Leave Your Message

6-10kV Oil Immersed Distribution Transformer - China Suppliers & Factory for Energy Efficiency and Low Noise

Product Description
Our high-permeability transformer is manufactured using premium cool-rolled silicon steel for the iron core, ensuring exceptional performance and energy efficiency. Designed without gaps in the magnetic path and featuring a high fill factor, this transformer offers enhanced concentricity and compact winding for both high voltage (HV) and low voltage (LV) coils. This state-of-the-art technology results in low energy consumption and minimal noise, making our transformers an optimal choice for power distribution systems. As a leading factory in China, we take pride in delivering reliable and high-performance transformers, establishing ourselves as a top supplier in the industry.

    Product Features

    1
    Our company's improved oil immersed distribution transformer iron core is made of imported high-quality cold-rolled silicon steel sheets stacked together, greatly reducing no-load losses and no-load currents. The iron core is tied to ensure its compactness and reduce noise.
    2
    The transformer connection group adopts the Dyn11 wiring method to reduce the impact of harmonics on the power grid and improve the quality of power supply.
    3
    The transformer is a fully sealed structure that extends its service life, eliminates the need for hanging cores, and requires no maintenance.
    4
    The high and low voltage windings are made of oxygen free copper. For low voltage windings of 500kVA and below, a double-layer cylindrical structure is used. For windings of 630kVA and above, a double helix or four helix structure is used. For high voltage windings, a multi-layer cylindrical structure is used.

    Transformer Standards

    GB 1094.1-2013: GB 1094.2-2013
    GB 1094.3-2017: GB 1094.5-2008
    GB/T 6451-2015: GB 7595-2017
    GB/T 25289-2010: GB 3837-2016

    Transformer Normal Service Conditions

    The height above the sea level is below 1000m
    Ambient temperature:
    Highest air temperature +40℃
    Highest daily average air temperature +30℃
    Highest annual average air temperature +20℃
    Lowest outdoor air temperature -25℃

    Transformer Special Service Conditions

    The height above the sea level is above 1000m
    Ambient temperature:
    Highest air temperature is above 40℃
    Lowest air temperature Lower than25℃

    Ordering Instructions

    When placing an order, the product model, rated capacity, high and low voltage ratings, high voltage tap range,number of phases, frequency, and connection group number should be provided.

    Transformer Model description

    Frequently Asked Questions

    What core material is used to minimize transformer losses?
    The iron core is made of imported high-quality cold-rolled silicon steel sheets stacked together, which significantly reduces no-load losses and currents while maintaining a compact, low-noise build.
    Why is the Dyn11 connection group adopted?
    The Dyn11 wiring method is used to minimize harmonic impacts on the electrical power grid, thereby improving overall power supply quality.
    Does this oil immersed distribution transformer require maintenance?
    No, it features a fully sealed structure that prolongs service life, eliminates core suspension/hanging requirements, and requires no ongoing maintenance.
    What winding structures are utilized for different capacities?
    All high and low voltage windings use oxygen-free copper. Low voltage windings are double-layer cylindrical (=630kVA), while high voltage windings utilize multi-layer cylindrical structures.
    What parameters are required when submitting an order?
    Please provide the product model, rated capacity, high and low voltage ratings, high voltage tap range, number of phases, frequency, and connection group number.