0102030405
6-10kV Oil Immersed Distribution Transformer from China Suppliers and Factory for Efficient Power Distribution
Product Features
1. High-Quality Core: Our company's improved oil immersed distribution transformer iron core is made of imported high-quality cold-rolled silicon steel sheets stacked together, greatly reducing no-load losses and no-load currents. The iron core is tied to ensure its compactness and reduce noise.
2. Dyn11 Wiring: The transformer connection group adopts the Dyn11 wiring method to reduce the impact of harmonics on the power grid and improve the quality of power supply.
3. Maintenance-Free: The transformer is a fully sealed structure that extends its service life, eliminates the need for hanging cores, and requires no maintenance.
4. Advanced Windings: The high and low voltage windings are made of oxygen free copper. For low voltage windings of 500kVA and below, a double-layer cylindrical structure is used. For windings of 630kVA and above, a double helix or four helix structure is used. For high voltage windings, a multi-layer cylindrical structure is used.
Transformer Standards
GB 1094.1-2013 : GB 1094.2-2013
GB 1094.3-2017 : GB 1094.5-2008
GB/T 6451-2015 : GB 7595-2017
GB/T 25289-2010 : GB 3837-2016
Transformer Normal Service Conditions
The height above the sea level is below 1000m
Ambient temperature:
Highest air temperature +40℃
Highest daily average air temperature +30℃
Highest annual average air temperature +20℃
Lowest outdoor air temperature -25℃
Transformer Special Service Conditions
The height above the sea level is above 1000m
Ambient temperature:
Highest air temperature is above 40℃
Lowest air temperature Lower than 25℃
Ordering Instructions
When placing an order, please provide:
The product model, rated capacity, high and low voltage ratings, high voltage tap range, number of phases, frequency, and connection group number.
The product model, rated capacity, high and low voltage ratings, high voltage tap range, number of phases, frequency, and connection group number.
Transformer Model Description
Frequently Asked Questions (FAQ)
What are the core features of your oil immersed distribution transformer?
It features an improved iron core made of imported high-quality cold-rolled silicon steel sheets, oxygen-free copper windings, and adopts the Dyn11 wiring method to reduce harmonic impact and improve power supply quality.
Is the distribution transformer maintenance-free?
Yes, the transformer features a fully sealed structure that effectively extends its service life, eliminates the need for hanging cores, and requires completely no maintenance.
What national standards do these transformers comply with?
Our transformers comply with standards including GB 1094.1-2013, GB 1094.2-2013, GB 1094.3-2017, GB 1094.5-2008, GB/T 6451-2015, GB 7595-2017, GB/T 25289-2010, and GB 3837-2016.
What are the normal ambient conditions for operating the transformer?
For normal service, the altitude should be below 1000m. The ambient temperature can range from a lowest outdoor air temperature of -25℃ up to a highest air temperature of +40℃.
Can the transformer operate in special service conditions?
Yes, under special service conditions, the transformer can operate at heights above 1000m and withstand ambient temperatures that are above 40℃ or lower than 25℃.
What information is required when placing an order?
When ordering, please provide the product model, rated capacity, high and low voltage ratings, high voltage tap range, number of phases, frequency, and connection group number.




