Application
The SC(B)10 resin-insulated dry-type transformer, designed using the advanced Dupont NOMEX paper insulation system from the USA, stands out among transformers produced in China. Our factory utilizes imported components, including high-quality German MKM copper foil, to ensure superior performance. With cutting-edge manufacturing technology, this transformer delivers high efficiency, minimal energy loss, and exceptional safety and reliability. It is particularly well-suited for high-rise buildings, airports, substations, commercial centers, and other environments that require anti-fire, anti-explosion, and anti-moisture features. As trusted suppliers in the industry, we are committed to providing top-notch transformers for various demanding applications.

,

    Product Features

    • Low loss, low operating costs, and significant energy-saving effects
    • Flame retardant, fire-resistant, explosion-proof, and pollution-free
    • Good moisture resistance and strong heat dissipation ability
    • Low partial discharge, low noise, maintenance free
    • High mechanical strength, strong short-circuit resistance, and long service life

    Structure

    3.1 Iron core

    The iron core is made of high-quality oriented cold-rolled silicon steel sheet material, with a 450 full diagonal joint structure. The core columns are tied with insulating tape, and the surface of the iron core is sealed with insulating resin paint to prevent moisture and rust. The clamps and fasteners are surface treated to prevent rust.

    In addition, Andeli has introduced fully automatic online iron core stacking equipment, which meets the high-precision, high-efficiency, and high standard requirements for iron core stacking in the production process, effectively reducing no-load losses, no-load currents, and iron core noise.

    Dry-Type Transformer Iron Core
    Low voltage foil coil

    3.2 Low voltage foil coil

    For low voltage and high current coils, the short-circuit stress is relatively high during short circuit, and the number of low-voltage turns is small. The larger the low-voltage current, the more prominent the problem of unstable ampere turns when using wire winding. The heat dissipation problem also needs to be considered. At this time using foil winding for low voltage can better solve the above problems.

    Firstly, foil products do not have axial turns and axial winding helix angles, and the ampere turns of high and low voltage windings are balanced. During short circuit, the axial stress of the transformer is relatively small. Secondly, due to their thin insulation and easy installation of multi-layer air ducts in the process, the heat dissipation problem can also be well solved. Our low-voltage foil coils are automatically wound on the automatic foil winding machine produced by STOLLBERG company in France. The internal welding is carried out on the winding machine using argon gas protection welding, which has high precision, low welding resistance, and no external welding process. DMD insulation is used between winding layers, and the rear end is sealed and cured with resin after winding.

    3.3 High voltage casting coil

    Main materials and characteristics:

    The coil uses F-grade insulated copper wire as the conductor, and glass fiber and epoxy resin composite material as the insulation. Its coefficient of expansion is similar to that of copper conductor, and it has good impact resistance, temperature change resistance, and crack resistance. All components of glass fiber and epoxy resin have self extinguishing properties, do not sustain combustion, and do not produce toxic gases or pollute the environment. Epoxy resin has good insulation properties and is particularly suitable for making high-voltage coils.

    High voltage casting coil 1High voltage casting coil 2

    3.4 Temperature control device and air cooling system

    Temperature control device malfunction alarm, over temperature alarm, over temperature trip, three-phase inspection, start stop for cooling device and other functions; The air cooling system adopts a cross flow top blowing cooling fan, which has low noise and high air pressure. The attractive appearance and other features enhance the overload capacity of the transformer. The temperature control adopts an intelligent temperature controller, which improves the safety and reliability of the voltage regulator operation.

    3.5 Schematic diagram of incoming line method

    Distribution transformers can be manufactured with conventional outgoing lines standard enclosed busbar outgoing lines, and standard side outgoing lines according to different interface forms, and special outgoing lines can also be designed according to user requirements.

    Transformer casing protection

    3.6 Protect the casing and output busbar

    Protect the casing and provide further safety protection for the transformer, with protection levels such as IP20 and IP23. The casing materials include cold-rolled steel plates, stainless steel plates, aluminum alloy plates, etc. for users to choose from. Low voltage outgoing lines use standard bus bars, both side and top outgoing lines can be used, and special appearance methods can also be designed according to user needs.

    Transformer Model description

    Transformer Model description

    Transformer Normal Service Conditions

    • Ambient temperature
    • Highest air temperature +40℃
    • Lowest air temperature -5℃
    • Hottest monthly average temperature +30℃
    • Hottest yearly average temperature +20℃
    • The height above the sea level is below 1000m
    • The power supply voltage, cave is similar to sine wave
    • Service Indoor

    Outline dimension diagram

    10KV distribution transformer outline dimension drawing 110KV distribution transformer outline dimension drawing 2
    10KV distribution transformer outline dimension drawing
    10KV Distribution Transformer IP20 with Shell Dimensional Drawing 110KV Distribution Transformer IP20 with Shell Dimensional Drawing 2
    10KV Distribution Transformer IP20 with Shell Dimensional Drawing

    Frequently Asked Questions (FAQ)

    What are the main features of your dry-type transformers?
    Our dry-type transformers feature low loss, low operating costs, and significant energy-saving effects. They are flame retardant, explosion-proof, pollution-free, and offer good moisture resistance, strong heat dissipation, low noise, and are maintenance-free with a long service life.
    How is the iron core of the transformer structured?
    The iron core is made of high-quality oriented cold-rolled silicon steel sheet material with a 450 full diagonal joint structure. It is tied with insulating tape and sealed with insulating resin paint to prevent moisture and rust, effectively reducing no-load losses and noise.
    Why do you use foil winding for low voltage coils?
    Foil winding balances the ampere turns of high and low voltage windings, reducing axial stress during short circuits. It also allows for thin insulation and easy installation of multi-layer air ducts, effectively solving heat dissipation problems for high current coils.
    What materials are used for the high voltage casting coil?
    The coil uses F-grade insulated copper wire as the conductor, and a glass fiber and epoxy resin composite material as the insulation. These materials provide good impact resistance, crack resistance, and self-extinguishing properties without producing toxic gases.
    What are the normal service conditions for this transformer?
    The transformer is designed for indoor service at an altitude below 1000m. The ambient temperature should range from a lowest of -5℃ to a highest of +40℃, with the power supply voltage wave being similar to a sine wave.
    What protection does the transformer casing provide?
    The casing provides safety protection levels such as IP20 and IP23. Users can choose from materials including cold-rolled steel plates, stainless steel plates, and aluminum alloy plates based on their specific needs and interface forms.