Application
The SC(B)10 resin-insulated dry-type transformer is expertly crafted using the Dupont NOMEX paper insulation system, ensuring superior quality and performance. Manufactured from premium imported materials, such as German MKM copper foil, this transformer represents the pinnacle of innovation in electrical solutions. With advanced manufacturing technology, our products provide exceptional performance, reduced energy loss, and enhanced safety and reliability. This transformer is ideal for high-rise buildings, airports, substations, and commercial centers, as well as other environments requiring fire resistance, explosion safety, and moisture protection. As a leading transformer supplier in China, our factory is committed to delivering high-performance electrical solutions tailored to meet the demands of modern infrastructure.

,

    Product Fectures

    Low loss, low operating costs, and significant energy-saving effects;
    Flame retardant, fire-resistant, explosion-proof, and pollution-free;
    Good moisture resistance and strong heat dissipation ability;
    Low partial discharge, low noise, maintenance free;
    High mechanical strength, strong short-circuit resistance, and long service life.

    Structure

    3.1 Iron core

    The iron core is made of high-quality oriented cold-rolled silicon steel sheet material, with a 450 full diagonal joint structure. The core columns are tied with insulating tape, and the surface of the iron core is sealed with insulating resin paint to prevent moisture and rust. The clamps and fasteners are surface treated to prevent rust.
    In addition, Andeli has introduced fully automatic online iron core stacking equipment, which meets the high-precision, high-efficiency, and high standard requirements for iron core stacking in the production process,effectively reducing no-load losses, no-load currents, and iron core noise.
    Dry-Type Transformer (1)

    3.2 Low voltage foil coil

    For low voltage and high current coils, the short-circuit stress is relatively high during short circuit, and the number of low-voltage turns is small. The larger the low-voltage current, the more prominent the problem of unstable ampere turns when using wire winding. The heat dissipation problem also needs to be considered. At this time using foil winding for low voltage can better solve the above problems. Firstly, foil products do not have axial turns and axial winding helix angles, and the ampere turns of high and low voltage windings are balanced. During short circuit, the axial stress of the transformer is relatively small. Secondly, due to their thin insulation and easy installation of multi-layer air ducts in the process, the heat dissipation problem can also be well solved. Our low-voltage foil coils are automatically wound on the automatic foil winding machine produced by STOLLBERG company in France. The internal welding is carried out on the winding machine using argon gas protection welding, which has high precision,low welding resistance, and no external welding process. DMD insulation is used between winding layers, and the rear end is sealed and cured with resin after winding.
    Dry-Type Transformer (2)

    3.3 High voltage casting coil

    Main materials and characteristics:
    The c il uses F-grade insulated copper wire as the conductor, and glass fiber and epoxy resin composite material as the insulation. lts coefficient of expansion is similar to that of copper conductor, and it has good impact resistance, temperature change resistance, and crack resistance. All components of glass fiber and epoxy resin have self extinguishing properties, do not sustain combustion, and do not produce toxic gases or pollute the environment. Epoxy resin has good insulation properties and is particularly suitable for making high-voltage coils.
    Dry-Type Transformer (3)
    Dry-Type Transformer (12)

    3.4 Temperature control device and air cooling system

    Temperature control device malfunction alarm,over temperature alarm, over temperature trip, three-phase inspection, start stop fork cooling device and other functions; The air cooling system adopts a cross flow top blowing cooling fan, which has low noise and high air pressure. The attractive appearance and other features enhance the overload capacity of the transformer, The temperature control adopts an inteligent temperature controller, which improves the safety and reliability of the voltage regulator operation.

    3.5 Schematic diagram of incoming line method

    Distribution transformers can be manufactured with conventional outgoing lines standard enclosed busbar outgoing lines, and standard side outgoing lines according to different interface forms, and special outgoing lines can also be designed according to user requirements.
    Dry-Type Transformer (5)

    3.6 Protect the casing and output busbar

    Protect the casing and provide further safety protection for the transformer, with protection levels such as IP20 and lP23. The casing materials include cold-rolled steel plates,stainless steel plates, aluminum alloy plates, etc. for users to choose from.Low voltage outgoing lines use standard bus bars, both side and top outgoing line scan be used, and special appearance methods can also be designed according to user needs.

    Transformer Model description

    Dry-Type Transformer (6)

    Transformer Normal Service Conditions

    Ambient temperature
    Highest air temperature re+40℃
    Lowest air temperature-5℃
    Hottest monthly average temperature +30℃
    Hottest yearly average temperature re+20℃
    The height above the sea level is below 1000m
    The power supply voltage,cave is simllar to sine wave
    Service Indoor

    Outline dimension diagram

    Dry-Type Transformer (7)
    Dry-Type Transformer (8)
    10KV distribution transformeroutline dimension drawing
    Dry-Type Transformer (9)
    Dry-Type Transformer (10)
    10KV Distribution TransformerlP20 with Shell Dimensional Drawing

    Frequently Asked Questions (FAQ)

    What are the main features of your dry-type transformers?
    Our dry-type transformers feature low loss, low operating costs, significant energy-saving effects, flame retardancy, explosion-proof design, good moisture resistance, low partial discharge, low noise, and high mechanical strength.
    What materials are used for the iron core?
    The iron core is made of high-quality oriented cold-rolled silicon steel sheet material with a 450 full diagonal joint structure. It is sealed with insulating resin paint to prevent moisture and rust, effectively reducing no-load losses and noise.
    Why do you use foil winding for low voltage coils?
    Foil winding balances the ampere turns of high and low voltage windings, significantly reducing axial stress during short circuits. It also allows for the easy installation of multi-layer air ducts, which solves heat dissipation problems effectively.
    What material is used for the high voltage casting coil?
    It uses F-grade insulated copper wire as the conductor and a glass fiber and epoxy resin composite material for insulation. This combination provides good impact resistance, crack resistance, and self-extinguishing properties without producing toxic gases.
    What functions does the temperature control device have?
    The intelligent temperature controller features malfunction alarms, over-temperature alarms, over-temperature trips, three-phase inspection, and controls the start/stop of the air cooling system to safely enhance the transformer's overload capacity.
    What are the normal service conditions for this transformer?
    The transformer is designed for indoor service at an altitude below 1000m. It operates in ambient temperatures ranging from -5℃ to +40℃, and requires a power supply voltage wave that is similar to a sine wave.