China 6-10kV Series Oil Immersed Distribution Transformer Suppliers & Factory for Energy Saving Solutions

,

Application
This transformer features a high-permeability cold-rolled silicon steel core, ensuring optimal performance with a high fill factor and no gaps in the magnetic path. The high-voltage (HV) and low-voltage (LV) coils are precisely wound around the core, providing excellent concentricity and compact design. With its energy-efficient technology, this transformer operates with low consumption and minimal noise pollution. As a leading product from trusted China suppliers, this transformer is ideal for use in power distribution systems. Our factory employs advanced methods to guarantee quality and reliability in every unit produced.

,

    Product Features

    1

    Our company's improved oil immersed distribution transformer iron core is made of imported high-quality cold-rolled silicon steel sheets stacked together, greatly reducing no-load losses and no-load currents. The iron core is tied to ensure its compactness and reduce noise.

    2

    The transformer connection group adopts the Dyn11 wiring method to reduce the impact of harmonics on the power grid and improve the quality of power supply.

    3

    The transformer is a fully sealed structure that extends its service life, eliminates the need for hanging cores, and requires no maintenance.

    4

    The high and low voltage windings are made of oxygen free copper. For low voltage windings of 500kVA and below, a double-layer cylindrical structure is used. For windings of 630kVA and above, a double helix or four helix structure is used. For high voltage windings, a multi-layer cylindrical structure is used.

    6-10kV series oil immersed distribution transformer (1)
    6-10kV series oil immersed distribution transformer (2)
    6-10kV series oil immersed distribution transformer (3)

    Transformer Standards

    • GB 1094.1-2013: GB 1094.2-2013
    • GB 1094.3-2017: GB 1094.5-2008
    • GB/T 6451-2015: GB 7595-2017
    • GB/T 25289-2010: GB 3837-2016

    Transformer Normal Service Conditions

    • The height above the sea level is below 1000m
    Ambient temperature:
    • Highest air temperature +40℃
    • Highest daily average air temperature +30℃
    • Highest annual average air temperature +20℃
    • Lowest outdoor air temperature -25℃

    Transformer Special Service Conditions

    • The height above the sea level is above 1000m
    Ambient temperature:
    • Highest air temperature is above 40℃
    • Lowest air temperature Lower than 25℃

    Ordering Instructions

    When placing an order, the product model, rated capacity, high and low voltage ratings, high voltage tap range, number of phases, frequency, and connection group number should be provided.

    Transformer Model Description

    Transformer Model description (1)
    Transformer Model description (2)
    Transformer Model description (3)

    Frequently Asked Questions

    What materials are used for the distribution transformer iron core?

    The improved oil-immersed distribution transformer iron core is made of imported high-quality cold-rolled silicon steel sheets. They are stacked and tied together to ensure compactness, significantly reducing no-load losses, no-load currents, and noise.

    What is the benefit of the Dyn11 wiring method?

    Adopting the Dyn11 wiring method for the transformer connection group helps reduce the impact of harmonics on the power grid, thereby improving the overall quality of the power supply.

    Does the transformer require regular maintenance?

    No, the transformer features a fully sealed structure that extends its service life, eliminates the need for hanging cores, and requires absolutely no maintenance.

    What materials are the high and low voltage windings made of?

    Both high and low voltage windings are made of oxygen-free copper. Low voltage windings use a double-layer cylindrical structure (for 500kVA and below) or a helix structure (for 630kVA and above). High voltage windings use a multi-layer cylindrical structure.

    What are the normal altitude and temperature service conditions?

    Under normal service conditions, the altitude should be below 1000m. The ambient temperature should not exceed +40℃, and the lowest outdoor air temperature should be -25℃.

    What information is needed when placing an order?

    When placing an order, you must provide the product model, rated capacity, high and low voltage ratings, high voltage tap range, number of phases, frequency, and connection group number.