China ZGS Series Box-Type Substation 10kV - Reliable Factory Suppliers for Efficient Grid Optimization

Enhance your power distribution efficiency with the ZGS13-H-/10 box-type substation, a leading solution from China’s top suppliers and factories. Featuring a distinctive M structure, this substation offers a compact and stable design, making it ideal for various applications. With its innovative 3-side air cooling system, you can expect an extended service life while the segregated compartments promote safer and simpler maintenance and operation. Trust in our product to optimize your grid while benefiting from quality and reliability

    Product Overview and Features

    The ZGS13-H-/10 series American-style box-type substation is a power equipment with advanced design concepts. Its unique "M"-shaped structure closely connects the substation with high- and low-voltage equipment, forming a unified whole. This integrated design not only improves equipment stability and safety, but also effectively saves installation space, meeting the demand for equipment integration in modern power systems.
    With three sides exposed to the air, the substation offers excellent heat dissipation, effectively reducing equipment temperature during operation and extending its service life. Furthermore, the substation's design allows for the separation of high- and low-voltage equipment housings from the main body of the substation, greatly facilitating routine maintenance and overhaul. Users can easily inspect and maintain equipment, reducing maintenance costs.
    In terms of core components, the ZGS13-H-/10 series substation utilizes a sheet-type oil tank, no oil pillow, and a fully enclosed S11 series oil-immersed transformer. These designs ensure efficient and safe operation of the transformer. Key components such as the high-voltage bushing, tap changer, oil level indicator, pressure relief valve, and oil drain valve are all installed in a high-voltage compartment on the end plate, ensuring safety and ease of operation. Meanwhile, the low-voltage bushing is installed in a low-voltage compartment on the end plate. This rational layout facilitates observation and operation, allowing users to quickly perform necessary monitoring and adjustments.
    The ZGS13-H-/10 series American-style box-type substation has become an ideal choice for urban and rural power construction and transformation with its superior design, good heat dissipation performance and convenient maintenance. It can meet the growing demand for electricity and provide users with a safe and stable power supply.

    Model Meaning

    Areas of application and environments of use

    It is widely used in various public places such as urban power grid renovation, residential neighborhoods, as well as indoor and outdoor places such as factories, mines, hotels, airports, railroads, wharves, highways and so on.
    • 1. The surrounding air temperature: the highest temperature +40℃, the lowest degree -25℃;
    • 2. Relative humidity:
      Daily average relative humidity: ≤95%; daily average water vapor pressure does not exceed 2.2kPa;
      Monthly average relative humidity: ≤90%; monthly average water vapor pressure does not exceed 1.8kPa;
    • 3. Altitude: below 1000m;
    • 4. Earthquake intensity: no more than 8;
    • 5. The surrounding air should not be corrosive or combustible gases, water vapor and other obvious pollution sites;
    • 6. No violent vibration places;
    • 7. Beyond the GB17467-2010《High-voltage /low-voltage pre-assembled substation》stipulated in the normal conditions of use, by the user and the company to negotiate.

    Frequently Asked Questions

    Q1: What are the main design advantages of the ZGS13-H-/10 series substation?
    It utilizes an advanced "M"-shaped structure that integrates high- and low-voltage equipment into a unified whole, improving stability, enhancing safety, and effectively saving installation space.
    Q2: How does this substation achieve efficient heat dissipation?
    The substation is designed with three sides exposed to the air, which provides excellent heat dissipation, significantly reduces operating temperatures, and helps extend the equipment's service life.
    Q3: Is the equipment easy to maintain and overhaul?
    Yes, the design allows the separation of high- and low-voltage equipment housings from the main body, greatly facilitating routine inspection and maintenance while reducing maintenance costs.
    Q4: What core components are used to ensure the safe operation of the transformer?
    It uses a sheet-type oil tank, no oil pillow, and a fully enclosed S11 series oil-immersed transformer. Key components are safely installed in dedicated high-voltage and low-voltage compartments on the end plate.
    Q5: In what environments and locations can this substation be applied?
    It is widely used in urban power grid renovations, residential neighborhoods, factories, mines, hotels, airports, railroads, and highways, both indoors and outdoors.
    Q6: What are the environmental condition requirements for normal operation?
    The surrounding air temperature should be between -25℃ and +40℃, relative humidity ≤95%, altitude below 1000m, earthquake intensity no more than 8, and the area should be free of corrosive or combustible gases and violent vibrations.