Leave Your Message

HXGN-12 10kV Fixed Ring High Voltage Switchgear - Reliable China Suppliers and Factory for Urban Power Solutions

,

The HXGN-12 box-type (fixed) metal-enclosed ring main unit (RMU) is an innovative high-voltage switchgear designed for modern urban power grid renovation and construction in China. This advanced RMU features a robust metal-enclosed structure that provides exceptional protection against environmental factors, ensuring reliable operation in diverse weather conditions. As a key solution from leading suppliers in the electrical equipment industry, it efficiently distributes high-voltage power while facilitating intelligent monitoring and management of the power grid. This enhances both the reliability and safety of electrical systems, making it a must-have for any power infrastructure project. Discover the unmatched quality and expertise from our factory to meet your high voltage needs.

,

    Product Overview and Features

    HXGN-12 type Box-type (fixed) metal-enclosed ring network switchgear (referred to as ring network cabinet) is a new type of high-voltage switchgear produced for the needs of urban power grid renovation and construction. The HXGN-12 ring main unit (RMU) was designed with urban space constraints in mind. Its relatively small size facilitates installation and maintenance in densely populated urban areas. Its modular design allows for flexible expansion and upgrades, adapting to changing power demands. By utilizing this highly efficient RMU switchgear, the power supply capacity and service quality of the urban power grid have been significantly enhanced, providing a more stable and reliable power supply for both residential and commercial users.
    In the power supply system as the opening and closing load current as well as closing short circuit current, this ring network cabinet with vacuum load switch, the operating mechanism for the spring actuator, the mechanism can be manually operated, can also be electrically operated. The switch and disconnecting knife are equipped with manual operating mechanism. The ring main unit is a complete set of strong, small size, no fire and explosion hazards, with reliable "five-proof" function.

    Model Meaning

    HXGN-12

    Areas of Application and Environments of Use

    Widely used in coal mines, iron and steel mills, cement factories, building ceramics, textiles, paper and other industrial and mining enterprises and hydroelectric power plants, solar photovoltaic power plants, wind power plants, thermal power plants and other power generation projects, substations, and power distribution rooms and other indoor places.
    • The surrounding air temperature: the highest temperature +40℃, the lowest degree -15℃.
    • Relative humidity:
      • Daily average relative humidity: ≤95%; daily average water vapor pressure does not exceed 2.2kPa;
      • Monthly average relative humidity: ≤90%; monthly average water vapor pressure does not exceed 1.8kPa.
    • Altitude: below 1000m.
    • Earthquake intensity: no more than 8.
    • Air Quality: The surrounding air should not be corrosive or combustible gases, water vapor, and other obvious pollution sites.
    • Vibration: No violent vibration places.
    • Special Conditions: Beyond the GB/T3906-2020 provisions of the normal conditions of use, by the user and the company to negotiate.

    Frequently Asked Questions

    What is the main purpose of the HXGN-12 ring main unit?
    It is specifically designed for the needs of urban power grid renovation and construction. Its compact and modular design adapts well to urban space constraints, providing a stable and reliable power supply for residential and commercial users.
    What type of switch does the RMU cabinet use?
    The cabinet utilizes a vacuum load switch with a spring actuator. The operating mechanism can be controlled either manually or electrically, offering flexibility in different operational scenarios.
    Where can the HXGN-12 switchgear be applied?
    It is widely applied in industrial and mining enterprises (like coal mines, steel mills, cement factories), as well as in various power plants (hydroelectric, solar, wind, thermal), substations, and power distribution rooms.
    What are the temperature requirements for operating this equipment?
    The equipment is designed to operate in surrounding air temperatures ranging from a maximum of +40℃ down to a minimum of -15℃.
    Are there any altitude or environmental limitations?
    Yes, the installation altitude should be below 1000m, and the earthquake intensity should not exceed 8. The surrounding air must be free from corrosive or combustible gases, and the site should have no violent vibrations.
    What safety features does the ring network cabinet include?
    The ring main unit is a strong, complete set with no fire and explosion hazards. It is equipped with a highly reliable "five-proof" safety function to ensure secure operation.

    Leave Your Message