Leave Your Message

JN15-12/31.5 Series Indoor High Voltage Ground Switch

JN15-12 indoor high voltage earth switch complies with requirement of GB1985-89 and lEC129 standard, it’s suitable for power system of 50Hz 12KV and below, and it can be used for earthing protection when equipped with various high voltage switch cabinets.
Advanced design, reliable technology;
Simple structure, easy installation;
Fast opening and closing capacity

    Using environment conditions

    Altitude:s 1000m;
    Ambient temperature:+40℃~-10℃
    (allowed for storage and transportation at 30℃℃)Earthquake intensity:≤ 8 degree.In place free of danger of flame and explosion, in places of no severe dust,chemical corrosion and no intense vibration.

    Structure

    Grounding switch structure is mainly composed of chassis l, flexible connection 2. adjusting locating ring 3, post insulator 4, static contact 5, contact spring 6, bus bar 7, moving contact knife 8, main shalt 9. control board 10, spiral energy storage spring ll,ete (as shown in figure 3, 4).According to user needs, it can also be equipped with electric display device and auxiliary switch
    Working principle
    When operating mechanism uses earthing switch to switch on, the applied moment uses the main shaft 9 to overcome the resistance torque and drive control board 10 along the switch-on direction.which makes the rocker on the moving contact knife 8 pass through spring dead point,and the spring releases energy to make the grounding switch fast switch on. In the closing position, the moving contact knife 8 firmly and reliably contacts through contact spring 6 and the flange (edge) of static contact 5.
    During opening operation, the applied moment make the main shaft 9 to overcome the main moment and torque spring force and drives the control board 10 to turn along the switch-on direction, which makes the rocker on the moving contact 8 to compress spring II to dead center, At this moment, the grounding switch switches off and the spring energy storage ends for another switching on.

    Outline and Mounting Dimension

    JN15-12 (2)
    JN15-12 (3)

    detail pictures

    JN15-12 (1)
    JN15-12 (2)

    Main technical parameters

    NO.

    Item

    Unit

    Parameter

    1

    Rated voltage

    kV

    12

    2

    Rated short-time withstand current

    kV

    31.5

    3

    Rated duration of short circuit

    S

    4

    4

    Rated short circuit making current

    kA

    80

    5

    Rated peak withstand current

    kA

    80

    6

    Interphase center distance

    mm

    150,210,275

    7

    Rated insulation level

    1min power frequency withstand woltage

    KV

    Phase-to-earth,
    Phase-to-phase
    Phase-to-phase

    42/48 75/85

    Lightning impulse withstand voltage