KYN28A-12(Z)(GZS1) Type Indoor Armored Withdrawable AC Metal-Enclosed Switchgear
Product Overview and Features
KYN28A-12(Z) type Armored move-open type a.c. metal-enclosed switchgear (hereinafter referred to as "switchgear") is suitable for three-phase a.c 50 HZ power system, used for accepting and distributing electric energy, and controlling, protecting and monitoring the electric circuit.This product conforms to the standards: GB/T3906 "3~35kV AC metal-enclosed switchgear", GB/T11022 "Standard Common Technical Requirements for High Voltage switchgear and Control Equipment", lEc60298 "AC Metal-enclosed Switchgear and Control Equipment with Rated Voltage of 1kV and Above".


The switchgear's compact structure facilitates installation in limited spaces, making it suitable for cities, industrial parks, and other power-intensive areas. Its modular design facilitates maintenance and upgrades, allowing users to flexibly configure the switchgear to meet the requirements of diverse power systems. Furthermore, the switchgear is equipped with advanced protection and monitoring devices that monitor circuit status in real time, promptly identifying and addressing potential faults and improving the safety and reliability of the power system.
By adopting the KYN28A-12(Z) armored removable switchgear, power companies can more efficiently manage power distribution, ensure a stable supply of electricity, and provide users with better power services. The widespread use of this equipment not only improves the overall efficiency of the power system but also lays the foundation for the intelligent and automated development of modern power networks.
Model Meaning

Areas of application and environments of use
Widely used in coal mines, iron and steel mills, cement factories, building ceramics, textiles, paper and otherindustrial and mining enterprises and hydroelectric power plants, solar photovoltaic power plants, wind power plants,thermal power plants and other power generation project sand substations, substations and power distribution room sand other indoor places.
1.The surrounding air temperature: the highest temperature+40℃,the lowest degree -25℃;
2. Relative humidity:
Daily average relative humidity: ≤95%; daily average water vapor pressure does not exceed 2.2kPa;
Monthly average relative humidity:≤90%; monthly average water vapor pressure does not exceed 1.8kPa;
3.Altitude: below 1000m;
4.Earthquake intensity: no more than 8;
5.The surrounding air should not be corrosive or combustible gases, water vapor and other obvious pollution sites;
6.No violent vibration places;
7.Beyond the GB17467-2010《High-voltage /low-voltage pre-assembled substation》stipulated in the normal conditionsof use, by the user and the company to negotiate.
Main technical parameters
| Name | Unit | Parameters | |||
| Switchgear technical parameters | |||||
| Rated insulation level | Rated voltage (V) | kV | 3.6 | 7.2 | 12 |
| 1min frequency withstand voltage | kV | 24 | 32 | 42 | |
| Lightning impulse withstand voltage (full wave) | kV | 40 | 60 | 75 | |
| Rated frequency | Hz | 50 | |||
| Rated current | A | 630,1250,1600,2000,2500,3150,4000 | |||
| 4s short-time withstand current | kA | 20,25,31.5,40,50 | |||
| Rated peak withstand current | kV | 50,63,80,100,125 | |||
| Protection class | Enclosure IP4X, IP2X for each compartment panel | ||||
| Vd4, VS1-12kV vacuum circuit breaker technical parameters | |||||
| Rated insulation level | Rated voltage (V) | kV | 3.6、7.2、12 | ||
| 1min frequency withstand voltage | kV | 42 | |||
| Lightning impulse withstand voltage (full wave) | kV | 75 | |||
| Rated frequency | Hz | 50 | |||
| Rated current | A | 630,1250,1600,2000,2500,3150,4000 | |||
| Rated short-circuit breaking current | kA | 16,20,25,31.5,40,50 | |||
| 4s short-time withstand current | kV | 16,20,25,31.5,40,50 | |||
| Rated peak withstand current | kA | 40,50,63,80,100,125 | |||
| Rated sequence of operation | Switch off-0.3S-Switch on-off180S-Switch on-off | ||||
| Rated short-circuit breaking current ≥40kA sequence | Second | 50 | |||