Leave Your Message

KYN61-40.5 Switchgear

KYN61-40.5 type Armored move-open metal-enclosed switchgear (hereinafter referred to as "switchgear") which is suitable for three-phase Ac50Hz power system, used for power plants, substations and industrial and mining enterprises in the distribution room to accept and distribute electricity, and the circuit control, protection and monitoring.

    Product Overview and Features

    The KYN61-40.5 armored, removable, metal-enclosed switchgear (hereinafter referred to as "switchgear") is a high-performance power device designed specifically for three-phase AC 50Hz power systems. It is widely used in power distribution rooms in power plants, substations, and industrial and mining enterprises. This switchgear primarily carries the electrical load, providing power to distribution equipment, distribution lines, distribution devices, and distribution cabinets, ensuring efficient operation of the power system.
    The equipment features an armored design with excellent protection, effectively resisting environmental influences and ensuring safe and stable operation under various operating conditions. The KYN61-40.5 switchgear's compact structure allows for flexible installation in space-constrained locations, making it ideal for modern power facilities. Equipped with advanced protection and monitoring devices, this switchgear monitors circuit operating status in real time, promptly identifying and addressing potential faults, thereby improving power system safety and reliability. Its efficient power distribution capabilities and flexible configuration options allow users to customize it to meet the needs of diverse power systems.
    KYN61-40
    KYN61-40
    The KYN61-40.5 armored removable metal-enclosed switchgear enables power companies and industrial users to more efficiently manage power distribution, ensure a stable power supply, and provide users with better power services. The widespread use of this equipment not only improves the overall efficiency of the power system but also lays a solid foundation for the intelligent and automated development of modern power grids.
    The product complies with the standards: GB/T3906 "3 ~ 35kV AC metal-enclosed switchgear", GB/T11022 "High-voltage switchgear and control equipment standard common technical requirements", lEC60298 "rated voltage of more than 1 kV and 50 kV below AC metal-enclosed switchgear and control equipment".

    Model Meaning

    KYN61-40

    Areas of application and environments of use

    Widely used in coal mines, iron and steel plants, cement plants, building ceramics, textile, paper and other industrial and mining enterprises and hydroelectric power plants, solar photovoltaic power plants, wind power plants, thermal power plants and other power generation projects and substations,substation distribution room and other indoor places.
    1.The surrounding air temperature: the highest temperature+40℃,the lowest degree -25℃;
    2. Relative humidity:
    Daily average relative humidity: ≤95%; daily average water vapor pressure does not exceed 2.2kPa;
    Monthly average relative humidity:≤90%; monthly average water vapor pressure does not exceed 1.8kPa;
    3.Altitude: below 1000m;
    4.Earthquake intensity: no more than 8;
    5.The surrounding air should not be corrosive or combustible gases, water vapor and other obvious pollution sites;
    6.No violent vibration places;7.Beyond the GB17467-2010《High-voltage /low-voltage pre-assembled substation》stipulated in the normal conditions of use, by the user and the company to negotiate.

    Main technical parameters

    Name Unit Parameters
    KYN61-40.5 type switchgear rated parameters
    Rated Voltage kV 40.5
    Rated current A 400, 630, 800, 1250, 1600, 2000
    Rated short-circuit breaking current kA 25,31.5
    Rated short-time closing current kA 63,80
    Dynamic stabilizing current(peak) kA 63,80
    4s thermal stabilizing current (rms) kA 25,31.5
    Rated insulation level Lightning Impact Withstand Voltage kV 185
    Main circuit 1min frequency withstand voltage kV 95
    Dimension(WxDxH)   1400x2800x2600
    Protection level Housing/Interior mm IP3X/IP2X
    ZN85-40.5 vacuum circuit breaker rated parameters
    Rated Voltage kV 40.5
    Rated current A 1250, 1600, 2000
    Rated short-circuit breaking current kA 25,31.5
    Rated short-time closing current kA 63, 80
    Dynamic stabilizing current (peak) kA 63,80
    4s thermal stabilizing current(rms) kA 25,31.5
    Rated insulation level Lightning Impact Withstand Voltage kV 185
    Main circuit 1min frequency withstand voltage kV 95
    Rated frequency Hz 50
    Rated sequence of operation   0-0.3s-CO-180s-CO
    Mechanical life time 10000
    Closing time ms 50~100
    Split time ms 35~60