Low Voltage Active Power Filter

Application
The working principle of an active harmonic filter is to detect the load current in real time.Based on a specified sub harmonic current detection algorithm,the harmonic current is gradually separated,and a control signal is generated according to the set filtering percentage to drive the IGBT to output a compensation current with the same amplitude and opposite phase as the load harmonic current,achieving the purpose of harmonic cancellation.

    Features

    Theory: Adopting a DSP+CPLD full digital control core, three-level topology technology, advanced harmonic detection algorithm, and PWM control strategy to achieve precise compensation of harmonic current.
    Operating frequency: 50HZ.
    Power grid structure: three-phase three-wire, three-phase four-wire.
    External current sampling channel: Two current sampling channel.
    Operation Mode: Harmonic, Unbalance.
    Harmonic current compensation: 2-50 times, Comprehensive harmonic compensation rate>92%.
    Full response time:<40ms.
    Stability: Capacities for 100% current limiting output to ensure long-term stable operation of the equipment
    Low Voltage Active Power Filter (1)
    Low Voltage Active Power Filter (2)

    Application

    Residential power distribution system 
    Automobile manufacturing industry
    Drainage and sewage treatment industry
    Data centers
    Steel industry
    Hospitals
    Metallurgical industry
    Pharmaceutical manufacturing industry
    Distributed photovoltaic industry 
    Light and textile industry
    Mining and industrial enterprises
    Semiconductor manufacturing industry
    Petrochemical industry

    Model Definition

    Low Voltage Active Power Filter

    Moudule Model

    Moudule Model
    Model Compensation capacity(kvar) System Voltage(V) Dimensions Width*Depth*Height(mm) Cooling System
    ADL APF-0.4-30A/4L-R 30 400 461*430*163 Forced air cooling
    ADL APF-0.4-50A/4L-R 50 400 461*430*163 Forced air cooling
    ADL APF-0.4-75A/4L-R 75 400 510*430*163 Forced air cooling
    ADL APF-0.4-100A/4L-R 100 400 643*496*213 Forced air cooling
    ADL APF-0.4-150A/4L-R 150 400 643*496*213 Forced air cooling
    ADL APF-0.4-200A/4L-R 200 400 573*500*280 Forced air cooling
    ADL APF-0.69-100A/4L-R 100 690 737*495*275 Forced air cooling
    ADL APF-0.8-100A/4L-R 100 800 737*495*275 Forced air cooling
    ADL APF-0.4-200A/4L-C 200 400 1000*1000*2200 Forced air cooling
    ADL APF-0.4-250A/4L-C 250 400 1000*1000*2200 Forced air cooling
    ADL APF-0.4-300A/4L-C 300 400 1000*1000*2200 Forced air cooling
    ADL APF-0.4-400A/4L-C 400 400 1000*1000*2200 Forced air cooling
    ADL APF-0.4-500A/4L-C 500 400 1000*1000*2200 Forced air cooling
    ADL APF-0.4-600A/4L-C 600 400 1000*1000*2200 Forced air cooling
    ADL APF-0.69-200A/4L-C 200 690 1000*1000*2200 Forced air cooling
    ADL APF-0.69-300A/4L-C 300 690 1000*1000*2200 Forced air cooling
    ADL APF-0.69-400A/4L-C 400 690 1000*1000*2200 Forced air cooling
    ADL APF-0.8-200A/4L-C 200 800 1000*1000*2200 Forced air cooling
    ADL APF-0.8-300A/4L-C 300 800 1000*1000*2200 Forced air cooling
    ADL APF-0.8-400A/4L-C 400 800 1000*1000*2200 Forced air cooling

    Technical Specification

    400V series 690V series 800V series
    Altitude < 2000m, Usage should be derated according to the international standard IEC 3859-2for altitudes above 2000 meters.
    Ambient Temperature -10-+50℃(derated above 40℃)
    Relative Humidity ≤ 90%, monthly minimum temperature 25℃, no condensation on the surface
    Pollution Level Below Level III
    Operating Voltage AC400V(-20%-+20%) AC690V(-20%-+20%) AC800V(-20%-+20%)
    Operating Frequency 50Hz
    Rated Compensation Capacity 30A,50A,75A, 100A,150A,200A   100A
    Power Grid Structure Three-phase three-wire,Three-phase four-wire
    Numbers in Parallel Unlimited
    System Efficiency ≥97%
    Switching Frequency 16kHz   12.8kHz
    Function Selection Harmonics,Harmonics+Unbalanced
    Compensation Scope 2-50 times, with adjustable compensation rate per time   2-25 times. with adjustable compensation rate per time
    Harmonic Compensation Rate >92%
    Full Response Time <40ms
    Noise <65dB
    Communication Rs485 Communication port
    Protection Overload, software/hardware over current,power grid over voltage/under voltage. power failure. over-temperature, frequency abnormality,short circuit protection   Overload, software/hardware over current, power grid over voltage/under voltage,power grid voltage imbalance. power failure. over-temperature, frequency abnormality,short circuit protection
    Installation Rack-Mounted, Wall-Mounted   Rack-Mounted
    Entry Line Method Rear Inlet(rack-mounted)Top Inlet (wall-mounted)   Rear Line
    Protection Level Ip20