Active Power Filter (APF) in Wastewater Treatment Plants
With the increasing attention of the country to environmental pollution issues, especially the emphasis on the treatment of water pollution that affects residents' health, the requirements for sewage discharge standards of enterprises are also gradually increasing. Therefore, sewage treatment plants are constantly improving their sewage treatment processes and introducing new sewage treatment equipment. However, the extensive use of non-linear loads has brought serious harmonic pollution and safety hazards to the power supply and distribution system of the entire sewage treatment plant.
1.The definition and generation of harmonics
Definition of harmonics: By performing Fourier series decomposition on periodic nonlinear sine waves, in addition to obtaining the components with the same frequency as the grid's fundamental frequency, a series of components with frequencies greater than the fundamental frequency of the grid by integer multiples are also obtained. This portion of the electrical energy is called harmonics.
Generation of harmonics: When current flows through the load, it has a non-linear relationship with the applied load voltage, which results in non-sinusoidal current and thus generates harmonics.
2.The Hazards of Harmonics
1)Harmonics can cause protection and automatic devices to malfunction or fail to operate properly, resulting in abnormal power outages and equipment disruptions, leading to significant additional losses.
2) The increase in the frequency of harmonic currents leads to a significant skin effect, causing the resistance of power cables and distribution line conductors to increase, resulting in greater line losses, increased heat generation, premature aging of insulation, shortened lifespan, and even damage. This makes it prone to ground short-circuit faults and creates fire hazards.
3) Triggering resonance in the power grid, resulting in harmonic voltages and excessive currents, causing serious accidents and damaging electrical equipment such as capacitor compensation devices.
4) Harmonic interference affects the normal operation of various electrical equipment. It causes additional losses and overheating in asynchronous motors and transformers. Secondly, it leads to mechanical vibrations, noise and overvoltage, reducing efficiency and utilization rate, and shortening the service life.
5) It causes interference to nearby communication, electronic or automatic control devices, and even makes them unable to function properly.
3.Governance Solution
The electrical equipment in the sewage treatment plant mainly includes pumps, agitators, blowers, etc. Generally, both fans and pumps require frequency conversion. However, frequency converters are a particularly large source of harmonics, which will cause particularly severe harmonic pollution and interference to the system, affecting its operation and frequently damaging electrical components. At the same time, there are also many power electronic components in the system, such as UPS and switching power supplies, which are all harmonic generating devices. Their normal operation depends on high-quality power supply. Once there is a power quality problem, it may cause equipment failure in the mild case and the entire system damage in the severe case. The resulting losses are difficult to estimate. Therefore, improving power quality is imperative.

4.The APF products have the following main features:
Filter out harmonics ranging from 2 to 50 cycles.
1)Three-level technology, modular design, high power density, easy maintenance;
2)Excellent air duct design leads to higher heat dissipation efficiency and longer component lifespan.
3)Dual-DSP and FPGA architecture, with triple logic protection, ensuring high system reliability.
4)Unique ascending-phase locking control and intelligent FFT technology achieve perfect compensation.
5)Supports multi-machine parallel operation, flexibly meeting the on-site needs of users.