Applications of Box-type Substations

2026-03-20

A box-type substation, also known as a prefabricated substation, is equipment used to transmit electrical energy from a high-voltage system to a low-voltage system. It is a complete set of power distribution equipment that integrates the distribution transformer, high-voltage and low-voltage switchgear, electrical energy metering devices, reactive power compensation equipment, connection lines, and auxiliary devices within a box enclosure. It is suitable for three-phase AC systems with a rated voltage of 10/0.4kV, serving for line and power distribution purposes.

Applications of Box-type Substations

1. Street Lighting Systems
Whether it is a European or American style box-type substation, they offer significant advantages over traditional brick-and-mortar electrical rooms in low-load systems. They are not only much more cost-effective but also aesthetically pleasing. European-style units can even feature landscape-oriented shells, turning a functional utility into a scenic element of the streetscape.
2. Residential Communities & Parks
Box-type substations are frequently used for power supply in parks and residential areas. These locations often prioritize aesthetics and space efficiency. Compact substations perfectly solve these challenges by offering a beautiful exterior design while occupying a minimal footprint.
3. Industrial & Mining Operations
Factories and mining sites often feature complex terrain and require rapid deployment to minimize downtime. Box-type substations are ideal for these environments due to their easy installation and reduced on-site construction requirements. With an IP55 protection rating, they can be installed directly in rugged terrains, significantly shortening construction periods.
4. Temporary Power Supply
Construction sites often require power sources that can relocate as the project progresses. Box-type substations offer excellent mobility and robust load capacity, making them the perfect solution for meeting temporary power demands on construction sites.
Precautions for Outdoor Installation of Box-type Substations
1. Grounding Conductor Specifications
The grounding conductor for the box-type substation must be made of copper, with a cross-sectional area of no less than 30mm². Be cautious of equipment with undersized grounding wires, as they are highly susceptible to lightning strikes and potential damage.
2. Grounding Network Requirements
Ensure the grounding network has sufficient coverage area and depth. Ideally, the grounding grid should be buried at least 1 meter underground. To further reduce resistance, it is recommended to install additional vertical grounding electrodes.
3. Site Selection & Safety Distances
Install the substation in an area free from severe vibration and impact. Avoid locations with strong electromagnetic induction. Ensure that the cable entry and exit lines maintain the necessary safety distances for construction and operation.
4. Environmental Conditions & Leveling
Select a dry and well-ventilated location for installation. The unit must be installed horizontally, with a tilt angle not exceeding 5 degrees.
5. Hazardous Material Restrictions
The installation site must be free from explosive hazards, as well as corrosive gases or liquids that could damage the equipment.
6. Unattended Operation Benefits
Designed for outdoor use without the need for on-site值班 (unattended operation), box-type substations feature a small footprint and low operating costs.
Operational Precautions for Box-type Substations
1. Avoid Long-term Overloading
Box-type substations should not operate under long-term overload. Especially after years of service, operators must monitor issues like coil aging and insulation degradation to prevent short circuits that could lead to fires.
2. Maintenance of Oil-immersed Transformers
If the substation is equipped with an oil-immersed transformer, regular inspections of the transformer oil's insulation performance are crucial. Replace the oil immediately if it fails to meet quality standards.
3. Monitor Core Heating and Insulation
Continuously monitor the transformer's operating status to prevent core overheating, which accelerates insulation aging. During maintenance, take extra care not to damage the insulation layers.
4. Check Wire Connections
During routine maintenance, pay close attention to wire contacts. Promptly address any loose connections or poor contacts, as these can generate excessive heat and pose a fire hazard.
5. Lightning Protection (Surge Arresters)
Surge arresters are installed in the high-voltage switchgear, transformer, and low-voltage switchgear. Their purpose is to prevent lightning strikes from damaging equipment, ensuring the safe operation of the substation.
6. Ventilation and Thermal Management
Ventilation and heat dissipation must be prioritized during the design phase, incorporating sufficient vents and exhaust fans. For instance,紫光 (Ziguang) box-type substations are equipped with exhaust fans in both the transformer and low-voltage compartments, along with an automatic temperature monitoring system, to effectively control internal temperatures.
Conclusion
Regular maintenance of the box type substation is essential for its normal operation.