Dry Type Transformer for Outdoor Installation
The SC(B) series is an indoor unit. A dry type transformer for outdoor installation needs a weather enclosure, and this series page does not print that enclosure.
Dry-type outdoor installation, in the manuals opened for this question, starts when the enclosure is built for weather. Service Indoor, the IP20 / IP23 casing, and a weather shield named by another maker have to stay in separate boxes.
A buyer at an outdoor pad wants a yes or a stop before the unit is ordered. On this series the stop is the indoor service line, read before anyone treats a casing level as rain protection.

What Outdoor Installation Asks of a Dry-Type
Other makers allow weather only when the enclosure is built for it. A ventilated dry-type stays an indoor machine until that enclosure is part of what was ordered.
One ventilated-dry-type manual says the units are for indoor use unless the enclosure is specifically designed for outdoor weather-proof service. Weather-proof service in those instructions means the enclosure was built for outdoor weather.
The same manual names NEMA Type 3R, or a weathershield kit printed on its own nameplate, as the outdoor construction it recognizes. Manufacturer NEMA 3R language stays with that manual.
A low-voltage guide from another maker says its encased ventilated units are for indoor service only unless they are converted. A rain shield can make NEMA Type 3R on that line, and the nameplate is where that maker prints the kit name.
A third installation guide treats a type 1 enclosure as indoor only. Type 3R, type 4, or type 12 may be used indoors or outdoors where that rating applies, and an outdoor site in that guide needs drainage and watertight cable entries.
A case manual puts indoor or outdoor use on the enclosure itself, and it tells the crew not to hose the unit. Suitability follows the case that was built, rather than a plan to stand open coils in the weather.
A specifying engineer comparing those manuals with a product page is checking the enclosure, not shopping for a winding story. If the page never names a weather enclosure, the manuals and the page are answering different purchases.
The pad question is simple once the manuals are lined up. Outdoor service, in those documents, is an enclosure fact, and the series page has to be read for whether it states that fact.
Indoor Service on the SCB Page
The SCB series page prints Service Indoor, which is the answer for a buyer who wanted this unit on an outdoor pad. Application copy can name high buildings, airports, substations, and commercial centers and still leave the service line indoors.
The normal-service block prints Service Indoor, highest air +40°C, lowest air -5°C, and altitude below 1000 m. That block is the air the page ties to indoor service.
| Printed line | What the service block says |
|---|---|
| Service | Indoor |
| Highest air | +40°C |
| Lowest air | -5°C |
| Altitude | below 1000 m |
Those buildings and sites are where fire, explosion, and moisture worry the specifier. A moisture worry on an application line still sits under an indoor service word, so it does not turn the coils into a yard installation.
The product named here is the SC(B) 6–10 kV dry-type. It is the resin-insulated series the application text describes, with tables under several SC(B) headings on the same page.
The series steps the high-voltage side printed on the page down to the low-voltage side on those tables. A waveform note asks for a supply that looks like a sine wave, which belongs with the indoor electrical description.
A procurement reader can hold the page and still find no outdoor service word next to the indoor one. The decision to stop is that indoor word, plus the outdoor kit the page leaves off.
The photographed unit shows three red coils on a blue frame, copper links, and a fan at the base. Those open coils are the indoor machine under discussion, and the frame around them is not an outdoor yard.

Enclosure versus Weather
IP20 and IP23 are the casing levels section 3.6 prints. They are a shell around the coils, and they sit apart from a weather shield.
The IP20 / IP23 casing is the shell printed around the coils, and that shell is separate from a weather shield. Reading either level as a weatherproof outdoor enclosure skips the step the manuals keep separate.
Professionally, those levels are protective-casing choices on an indoor page. In plain language, the shell is the metal around the coils, and a rain cover is a different object that this page does not name.
Section 3.6 also prints casing metals and low-voltage outgoing lines that use standard bus bars. That hardware is an enclosure choice on the indoor page, beside the service block already quoted.
A buyer who treats IP23 as leave to face the rain is using a casing level as a weather rating. The opened manuals keep a ventilated indoor casing and a weather shield as two steps, and this page prints only the first.
The side view shows a blue cabinet on one end, open channel feet, and the red coils still visible. A closed side panel in that photo is part of the frame on display, and it is not labeled as a weather shield.

Air and Altitude the Site Must Match
The printed band is indoor air, and the room has to match it. Altitude on that same block stays with the indoor service line rather than with a yard.
A loading thread says to look at the room and keep the location well ventilated before the unit runs near its load. Ventilation is a site fact: tight air around the coils is a problem even when the room itself is indoors.
That thread is a loading question, not an outdoor kit. Loading-guide figures the poster did not quote from a purchased standard stay out of this pre-check.
A TestGuy maintenance note on liquid-filled equipment puts ambient and temperature rise on the nameplate of the unit in front of you. Pasting another machine's rise onto this series would invent a figure the SCB page does not print.
Federal energy rules define a medium-voltage dry-type as a distribution transformer whose core and coil sit in a gaseous or dry compound. The same definition leaves a nonventilated transformer outside the distribution-transformer class, and the class is not an outdoor permit.
Monthly and yearly air averages are also printed on the service block. They describe the indoor air the page expects, and they do not convert the series into an outdoor unit.
The base of the photographed frame carries a silver fan under the coils. That fan is there to move air, which matches the ventilation worry, and it adds no weather rating to the nameplate.
An indoor room that is hot, tight, or far above the printed altitude band is already outside the service block. Fixing that room is an indoor problem, and it is a different job from buying a rain cover.
What a Weather Shield Is and Is Not
Installers on a forum thread describe a shield for rain, and Andeli does not print a shield part. Weather shield is the name they use for that rain cover, and it is someone else's part.
Important: On a forum thread, installers said a weather shield is for rain and not for water from a sprinkler.
The same thread says an indoor dry-type can go outdoors with the correct manufacturer's weather shield. The correct shield is the one that maker names, so a remembered kit number aimed at Andeli asks for a part this page does not print.
A later comment says a NEMA 3R cover may fall short in driving rain and high humidity, and that a different enclosure may be wanted. That caution belongs to the thread, and it is not an enclosure type printed for this series.
A weather shield and sprinkler protection answer different water. Rain falls on the cover, while water from a sprinkler is thrown at the unit, and the installers separated those two.
If the room uses sprinklers, or if a crew expects to wash the case, the thread already treats a rain cover as the wrong object. This series page does not offer another object in its place.
Asking the factory for a shield part number only helps when the page or the nameplate prints one. Here the page is silent, so the honest pre-check ends on that silence.
What Andeli Prints and Does Not Print
Indoor service, the air band, and the casing levels are printed. Outdoor kits and wall gaps are left off, which closes the pre-check.
Andeli prints indoor service, the air band, and the casing levels, and leaves off a weather shield, a NEMA type, an outdoor service line, a wall clearance, and a pad height. A buyer who needs those outdoor details has to get them from a document that actually prints them.
| Topic | What the SCB page prints | What other makers add for weather |
|---|---|---|
| Service | Service Indoor | A weather enclosure or a named shield |
| Casing | IP20 / IP23 casing | Kept separate from the rain cover |
| Shield part | Left off the page | Named on that maker's nameplate |
| Wall gap | Left off the page | A maker-tested gap, sometimes remembered as six inches |
| Pad height | Left off the page | Stays in that maker's own outdoor note |
The SCB series dry-type transformer is the indoor resin unit to open when the room matches Service Indoor. Use that page for the series that was printed, and keep the unit off an outdoor pad that still needs a weather enclosure.
It fits a building whose air and altitude sit inside the printed indoor band, including sites named for fire or moisture worry inside that building. It is the wrong purchase when the site is outdoors and the reader needs a weather shield or a NEMA outdoor type, because this page prints neither.
The transformer catalog is the upward path into the rest of the line. Stay on the product page when the room matches the indoor band, and start a different enclosure conversation when the site is outside.

The labeled view shows the coils, the clamp frame, the fan, and the mounting feet. Those feet are the base of the indoor frame in the photo, and the page prints no outdoor pad height beside them.
A remembered wall clearance belongs on the same absence list. Forum posts argue gaps, including six inches, as whatever that maker tested, so a remembered inch is not an Andeli dimension.
FAQs
Does the SCB page allow outdoor installation?
The SCB page prints Service Indoor and leaves outdoor service off the page. Setting this series outdoors would need an enclosure step the page does not print.
Do IP20 and IP23 mean a weatherproof outdoor enclosure?
The IP20 / IP23 casing is the shell printed around the coils, and that shell is separate from a weather shield. Treating IP23 as a weatherproof outdoor enclosure treats a casing level as a step the page never prints.
What do other makers add before a ventilated dry-type sees rain?
One ventilated-dry-type manual says the units are for indoor use unless the enclosure is specifically designed for outdoor weather-proof service. Other makers name a weather shield or a NEMA Type 3R kit on their own nameplate before a ventilated unit sees rain.
Is a weather shield the same thing as sprinkler protection?
On a forum thread, installers said a weather shield is for rain and not for water from a sprinkler. Rain on a cover and water thrown by a sprinkler are different, and the shield they described was only the rain cover.
What air temperature and altitude does the SCB service block print?
The normal-service block prints Service Indoor, highest air +40°C, lowest air -5°C, and altitude below 1000 m. Monthly and yearly averages sit on that same indoor block and stay with indoor service.
What outdoor details does the Andeli page leave off?
Andeli prints indoor service, the air band, and the casing levels, and leaves off a weather shield, a NEMA type, an outdoor service line, a wall clearance, and a pad height. Those missing outdoor details have to come from a document that prints them.
Why is a remembered wall clearance not an Andeli dimension?
A forum argued ventilation gaps, including six inches, as whatever that maker tested. A remembered wall clearance is that argument, and it is not an Andeli dimension.
References
- Energy-conservation definitions for distribution transformers, including the medium-voltage dry-type definition: https://www.ecfr.gov/current/title-10/chapter-II/subchapter-D/part-431/subpart-K.
- Physics Forums thread on keeping a transformer location well ventilated near its load: https://www.physicsforums.com/threads/can-i-load-a-1000-kva-transformer-to-90-with-ambient-temperature-limits.927047/.