Earthing Switch Diagram
An earthing switch diagram is the named mark on a single-line drawing, while the JN15 page prints the knife, the spring, and the ratings table. The searched wording is a single line diagram triangle with e symbol earthing switch, and the opened sheet names an earth general symbol instead of drawing that triangle.
A drawing office wants a small mark it can drop on a feeder sheet. A cabinet buyer wants the metal, the closing action, and the ratings row, and those two requests only share a name.

What the Triangle Phrase Is Asking
The searched phrase is asking for a single-line mark, and the JN15 page prints the hardware and the table instead of that glyph. A buyer who pastes a triangle onto the JN15-12 ground switch is borrowing a sketch the product page never drew.
Important: On an electronics forum, a poster said the common mark looks like a triangle pointing down, while the earth mark they described has three or four diagonal lines.
That post keeps two sketches apart. The common mark is a stack of lines the poster compared with a downward triangle, and the earth mark in the same post is a set of diagonal lines.
The mix-up starts on a schematic, before a switch page is opened. A horizontal stack and a run of diagonal strokes come from different drawing habits, and neither stroke is the JN15 knife.
People then carry the triangle into a search for an earthing switch. The words single line diagram triangle with e symbol earthing switch are that search, and the page behind the hardware name is a mechanism description plus a ratings table.
Read the phrase as a request for a drawing mark. Read the JN15-12 ground switch page as cabinet earthing hardware, with a closing story and a table, rather than as a symbol library.
On a single-line sheet, one circuit is one line, and a small mark stands in for a device so the feeder, the breaker, and the earth connection can share a page. The studio photograph shows insulators, a copper bar, coil springs, and braided leads, which is a different deliverable from that mark.
The forum line shows how the triangle story starts. It stops there, and it does not hand over a symbol name, a parts list, or a ratings row for this switch.
What the Opened Symbol Sheet Names
The opened symbol sheet names an earth general symbol and a combined disconnector and earthing switch. Earth general symbol is the label on that sheet, and in plain words it is the earth mark the sheet names.
The combined label sits next to the earth label. A short note says individual actuator equipment may be added, so the drawing can grow extra actuator parts beside the combined device.
That note stays with the symbol assembly. The JN15 knife, the shaft, and the spring show up in the mechanism paragraph, with figure callouts, rather than under a symbol name.
| Label source | Words printed | What the reader takes |
|---|---|---|
| Opened symbol sheet | Earth, general symbol | The earth-mark label |
| Opened symbol sheet | Combined disconnector and earthing switch | The combined-device label |
| JN15-12 mechanism paragraph | Moving contact knife, main shaft, spring dead point | The closing story |
| JN15-12 ratings table | Short-time withstand cell | The unit the cell prints |
IEC 60617's opened preview includes single-line diagrams in the overview-diagram class. The preview sorts kinds of diagrams, and a single-line diagram is one class inside overview diagrams, alongside block diagrams.
The preview text that was opened does not draw the triangle from the forum post. The sheet text that was opened names the two labels and stops.
A specifier who needs the earth general symbol should take that label from the sheet. A specifier who needs the JN15 closing action should stay with the mechanism words on the product page.
The two sources serve two desks. One desk is placing marks on a single-line sheet, and the other desk is checking what the indoor switch is built from.
Opened samples of the equipment standard list test-arrangement figures, and their contents also name an informative list of symbols. The symbol drawings themselves are not in the sample text that was opened, and those test arrangements are not the JN15 outline.
The catalog record covers alternating current disconnectors and earthing switches for indoor and outdoor installations. That record is the equipment family, and it is not a drawing of the JN15 knife.
What the JN15 Page Prints
The JN15-12 page says the switch is for earthing protection in high-voltage switch cabinets on the power system that page names. The JN15-24 page adds short-circuit making capacity and the fields a buyer fills in on the order.
On the JN15-12 page, the duty is earthing protection when the switch is equipped with various high-voltage switch cabinets. The page also names GB1985-89 and the second standard mark printed beside that code.
The JN15-24 page says the switch has short-circuit making capacity so the switchgear is spared damage, and it is used for earthing protection during repair when it is fitted in high-voltage switch cabinets. The JN15-24 page is for a system of 24KV 50(60)Hz, and the soft connection is normally L=400mm.
The order asks for a model number, an operating mode, a phase distance, and a voltage indicator. Operating mode means right or left operation, and in plain words it tells which side the handle is on.
Phase distance on that order is a field the buyer states. It is separate from the interphase center-distance cell on the JN15-12 table, which stays on its own row.
The JN15-24 page says it complies with the standards printed in its general paragraph. Those printed names stay on that page, and they are order context rather than a single-line glyph.
A cabinet builder reading this page is checking whether the switch earths the circuit for protection, and whether the order captures side of operation, phase distance, and the indicator. The drawing mark, if the job needs one, still comes from the symbol sheet.
A Mechanism Sentence Is Not a Symbol
The page describes a moving contact knife, a main shaft, and a spring dead point, and that description is the mechanism. Spring dead point is the place in the closing sentence where the spring takes over, and in plain words it is the moment the spring drives the knife shut.
On closing, the moment on the main shaft drives the control board until the moving-contact rocker passes the spring dead point, and the spring then closes the switch. The knife contacts the flange of the static contact through the contact spring.
The switch is composed of a chassis, flexible connection, adjusting locating ring, post insulator, static contact, contact spring, bus bar, moving contact knife, main shaft, control board, and spiral energy storage spring. The page points at figure 3 and figure 4 for that assembly, and it says an electric display and an auxiliary switch can be fitted.
A reader who treats the closing sentence as a single-line mark is reading a motion story as a glyph. The sentence tells how the rocker passes the spring dead point and how the spring finishes the close.

The opposite view shows the same kind of assembly: three ribbed insulators, a copper bar, coil springs, and braided leads on a metal frame. The spring dead point is a moment in the closing sentence, and the photograph shows the springs and the knife hardware rather than a drawing mark.
The chassis, the post insulators, and the bus bar are parts you can point at. The spring dead point is the handover in the motion, after the rocker passes it and the stored spring finishes the close.
The contact spring is the part the knife uses against the flange of the static contact. The flexible connection is the braided lead in the parts list, visible at the side of the frame.
An electric display and an auxiliary switch are optional fittings the page allows. They are add-ons to the same mechanism, and they are still not a symbol name from the opened sheet.
Ratings That Stay on the Table
Making current and peak withstand current stay on the JN15-12 rows that print them, and the short-time withstand cell keeps the unit that cell prints. Making current is the short-circuit making cell on the table, and in plain words it is the current that cell says the switch can close onto.
The JN15-12 table prints rated voltage 12 kV, rated short circuit making current 80 kA, and rated peak withstand current 80 kA. The same JN15-12 table prints rated short-time withstand current with the unit kV and the parameter 31.5.
The JN15-12 interphase center distance cell prints 150,210,275 mm. Those center distances stay in that cell, and they are not copied onto the JN15-24 order line.
Someone who rewrites the short-time unit is trying to tidy a cell that already shows a unit. The short-time withstand cell should be quoted as the row shows it, so a later reader sees the same unit the table shows.
| Item | Unit | Parameter |
|---|---|---|
| Rated voltage | kV | 12 |
| Rated short-time withstand current | kV | 31.5 |
| Rated duration of short circuit | S | 4 |
| Rated short circuit making current | kA | 80 |
| Rated peak withstand current | kA | 80 |
| Interphase center distance | mm | 150,210,275 |
The insulation row is not a clean pair, so this reading leaves it off. On the JN15-24 table, the power-frequency cell and the lightning cell are also left unread, because they are not a clean pair with a unit on every line.
The JN15-24 table prints mechanical life 2000 time. The cell uses the word time, so the life row stays in that printed wording.

The same hardware sits here on a concrete floor, with the insulators, the springs, the copper bar, and the braided leads still in view. The ratings stay on the table, and the photograph does not carry a ratings row of its own.
Peak withstand current and making current are neighbors on the JN15-12 table, and each one keeps its own row. Moving either number onto the short-time withstand cell would mix rows that the table printed separately.
What the Page Does Not Print
The opened JN15 pages print no triangle, no torque, and no racking sequence. The pages do not print a single-line triangle with an E, a bolt torque, or a racking interlock sequence.
A pre-check stops on those gaps. The glyph belongs with the symbol sheet, the closing motion belongs in the mechanism paragraph, and the ratings belong on the row that printed them.
The JN15-12 indoor ground switch is the page that prints the mechanism and the table. The grounding switch range is the cabinet-earthing group around that page.
A reader who needs a drawn glyph, a torque chart, or a rewritten short-time unit will leave those three points off this page. Open the product page for the table and the mechanism words, and take the symbol from the drawing sheet.

The frame above is the outline table from the same gallery, with a model column and three lettered columns. It sits beside the ratings table, and it still does not draw a single-line mark.
Torque is absent, so no bolt value is available to copy. A racking interlock sequence is also absent, and this page does not take over the switchgear test write-up that would own that sequence.
What remains is enough for the decision this hardware page can support. The JN15-12 ground switch earths the cabinet circuit for protection, the spring dead point is the handover in the close, and the earth general symbol stays a label on the opened sheet.
FAQs
What does the JN15-12 page say the switch is for?
The JN15-12 page says the switch is for earthing protection in high-voltage switch cabinets on the power system that page names. The duty is cabinet earthing when the switch is fitted in those cabinets.
Does that page print a single-line triangle with an E?
The pages do not print a single-line triangle with an E, a bolt torque, or a racking interlock sequence. The page prints the knife, the spring, and the ratings table.
What rated voltage and making current does the JN15-12 table print?
The JN15-12 table prints rated voltage 12 kV, rated short circuit making current 80 kA, and rated peak withstand current 80 kA. The making-current cell and the peak cell are separate rows on that table.
Why is the short-time withstand unit left as the cell prints it?
The short-time withstand cell is left as printed so the unit is not swapped in silence. The same JN15-12 table prints rated short-time withstand current with the unit kV and the parameter 31.5.
What does the spring-dead-point sentence describe?
The sentence describes the closing motion, where the main shaft drives the control board until the moving-contact rocker passes the spring dead point and the spring then closes the switch. The knife then meets the flange of the static contact through the contact spring.
What does the JN15-24 page ask for on the order?
The order asks for a model number, an operating mode, a phase distance, and a voltage indicator. The JN15-24 page is for a system of 24KV 50(60)Hz, and the soft connection is normally L=400mm.
What does IEC 60617's opened preview say a single-line diagram is?
IEC 60617's opened preview includes single-line diagrams in the overview-diagram class. A single-line diagram sits in that overview class beside block diagrams.
References
- The catalog record covers alternating current disconnectors and earthing switches for indoor and outdoor installations. Disconnector and earthing-switch catalog record.
- The opened preview places single-line diagrams in the overview-diagram class. Opened preview of the diagram-symbol standard.
- The opened symbol sheet names an earth general symbol and a combined disconnector and earthing switch. Community symbol sheet.