A harmonic filter diagram is two different drawings, and this page prints the active one. The passive drawing is an LC branch in parallel with the non-linear load, and the electrical installation guide is where that branch is named. The active drawing is the compensation current on the Andeli page, and the page prints no reactor value and no capacitor value.
A buyer who types the shared name can open a circuit sheet or a working-principle paragraph. One sheet is about where a tuned branch sits. The other is about the current an active unit sends back toward the load.
The hardware in the photographs is the low-voltage active power filter. The page names three-phase sites, including data centers, hospitals, and industrial plants. The photographs show the chassis, and the words under them are the principle the page actually prints.

The wall-mount chassis has terminal blocks along the top, a warning label on the side panel, ventilation slots, and a mounting ear. That photograph is the active unit under the title. It is a chassis view for the injection paragraph, and a reader still has to read the paragraph to see what the unit does.
Two Drawings Share This Name
One drawing is a passive branch, and the other is an active injection. Active injection is the controlled current an active unit sends against the harmonic. In plain words, it is a current sent back so the feeder carries less of that harmonic.
The electrical installation guide sorts harmonic filters into passive, active, and hybrid. In that guide, a passive filter is an LC circuit tuned to a harmonic order and installed in parallel with the non-linear load. An active harmonic conditioner in the same guide is also installed in parallel, and it injects the opposite harmonic current so the line current stays sinusoidal.
Hybrid filters in that guide combine the tuned branch and the injection. The Andeli page prints the active case, which is the injection paragraph. A reader who needs the tuned branch still goes to the guide, because the product text is the current sentence.
Search results put both drawings under one name, which is why a submittal can pick up the wrong sheet. A specifying engineer may ask for a harmonic filter diagram and receive either a circuit or a principle paragraph. Naming the drawing before the review starts keeps the circuit with the guide and the current sentence with Andeli.
The collision shows up in procurement when a package lists one line and the vendor attaches the other document. The line is still the same words. The attachment is either a branch layout or an injection description, and those attachments do different work in a review.
What a Passive Circuit Diagram Shows
A passive harmonic filter diagram shows an LC branch in parallel with the non-linear load. People also search that sheet as a harmonic filter circuit diagram. In the electrical installation guide, the branch is the passive filter, placed beside the load that draws the harmonic.
The professional reading is a resonant side path tuned for a chosen harmonic order. The plain reading is a tuned trap drawn next to the equipment.
The electrical installation guide is the source of that parallel branch. The Andeli page is a separate document, and its printed principle is the injection current.
Passive-filter model help lists series single-tuned, high-pass, band-pass, and C-type layouts. A single-tuned filter in that help is defined from the harmonic order, the capacitive reactive power, and the quality factor, along with system frequency and voltage. Those inputs belong to that model library.
A low-voltage design note treats a single-tuned notch as a shunt branch. One layout there is a delta-connected capacitor bank with an inductance in series.
That layout is an example of the passive sheet. It stays with the note that printed it.
Important: On a forum thread, a poster asked whether a shunt passive filter still works if the non-linear load is not connected to ground.
The same thread asks whether a delta connection blocks the third harmonic. A reply says the shunt filter has to connect in parallel with the load, and the return path is the second conductor.
The worry is about a closed path around the load. The answer on the thread puts that path on the paralleled conductors.
A buyer who expected the LC branch on the Andeli page is holding an injection paragraph while asking a tuning question. The parallel branch, the notch example, and the forum argument about the return conductor all belong with the passive sheet. The product page prints the IGBT current instead.
What the APF Page Prints Instead
The low-voltage active power filter page prints an opposite-phase IGBT current, and the series block prints the compensation line. The application paragraph says the filter detects the load current, separates the harmonic current, and generates a control signal from the set filtering percentage to drive the IGBT. The IGBT outputs a compensation current with the same amplitude and opposite phase as the load harmonic current.
That sentence is the active injection this page prints. The professional meaning is a compensation current of the same amplitude and opposite phase.
The plain meaning is a current pushed back against the load harmonic. A buyer who reads the sentence as a reactor size has switched questions in the middle of the paragraph.
The 400 V series block prints a compensation scope of 2-50 times, a harmonic compensation rate greater than 92%, and a full response time less than 40 ms. That printed line is what a buyer can quote for range, rate, and response. The same block is the place those three statements sit together.
The page also names DSP and CPLD control and a three-level topology. It lists three-phase three-wire service and three-phase four-wire service. It names two external current sampling channels, and the operation modes on the page are Harmonic and Unbalance.
A site with a neutral reads the four-wire line, and a site without one reads the three-wire line. The sampling channels are the path the paragraph gives for seeing load current before the harmonic part is separated. The mode names tell a reader that harmonic operation and unbalance operation are both printed choices.

The rack chassis shows a front grille of cooling fans, two side handles, and ventilation along the side panel. The nameplate area is on the top surface. The photograph is the hardware a walk-through can point to while the injection sentence stays in the text.
Which Drawing Answers Which Question
The LC drawing answers a tuning question, and the Andeli paragraph answers an injection question. Ask where the trap sits, and the electrical installation guide is the sheet. Ask what current the active unit sends, and the IGBT sentence is the sheet.
| Drawing | Question it answers | Where the reader looks |
|---|---|---|
| Passive harmonic filter diagram | How the LC branch sits beside the load | Electrical installation guide |
| Active injection paragraph | What current the IGBT sends | Andeli low-voltage active power filter page |
| Hybrid description in the guide | How a branch and an injector are combined | Electrical installation guide |
A package review starts from the question the attachment is supposed to answer. Tuning talk stays with the parallel branch.
Injection talk stays with the compensation current. Hybrid talk stays with the guide's combined description, and the Andeli paragraph is the injection case on its own.
The model-code image is a naming key for the series, with callouts running from the organization code through the product code. It labels compensation current, installation mode, and voltage level as fields in the name.
A reader uses it to parse a model string. The chassis photos remain photographs of the enclosure.

The legend is wide and linear, with leader lines from each block of the code to a short label. Installation mode on that legend names drawer, wall mounting, and cabinet forms.
The legend explains the code. Electrical behavior stays in the injection paragraph.
Calculator Values Stay on That Page
The calculator page says the simple LC resonance model does not apply to an active filter. The LC resonance model is the passive tuning sum the calculator is built to run. In plain words, it is a formula for a tuned branch, and the page that hosts it stops the formula at an active unit.
A buyer sometimes wants a calculator printout copied onto a nameplate. The calculator is written for a passive single-tuned filter.
The printout answers that filter. The active unit is described by the injection paragraph and by the series-block line, so the printout stays on the calculator page.
The harmonic filter design calculator is the page that states the limit. Open it when the task is a passive single-tuned calculation. Leave the result there when the equipment under review is the Andeli active filter.
Model-library inputs for a single-tuned branch, such as harmonic order, capacitive reactive power, and quality factor, stay with that library. They describe how that model is defined. They are a different list from the compensation line the Andeli series block prints.
Pasting a passive result onto the active nameplate answers a machine the calculator has already set aside. The nameplate conversation for this unit quotes the injection sentence and the series-block line. The tuned-branch arithmetic remains on the calculator page that owns it.
What Andeli Prints and Does Not Print
The principle and the range are printed. The page prints no reactor value and no capacitor value. A buyer can quote the IGBT sentence and the series-block line, and a reactor or capacitor figure has to come from a passive-filter document.
| Item | What the Andeli page shows |
|---|---|
| Compensation line | 2-50 times |
| Harmonic compensation rate | Greater than 92% |
| Full response time | Less than 40 ms |
| Reactor value | Left off the page |
| Capacitor value | Left off the page |
The low-voltage active power filter is the page that prints the injection principle and the compensation line. Open it when the next question is the current the IGBT sends. When the next question is a passive LC branch or a reactor value, take the drawing from a passive-filter document.
Related power-quality reading on this site sits on the power quality hub. That hub is the upward path. The product page is the downward path for this active unit.

This rack view shows the fan grille, the side handles, and a connector on the side panel. It is the chassis a reader can match to the injection paragraph. A submittal that needs the enclosure can use the photograph with that paragraph, while a submittal that needs the LC branch still uses the installation guide.
The active page tells a buyer what current the IGBT sends and what the series block prints for range, rate, and response. A passive schematic, with its reactor and capacitor values, remains the other drawing.
FAQs
What does a passive harmonic filter diagram show?
A passive harmonic filter diagram shows an LC circuit in parallel with the non-linear load. The electrical installation guide is the source of that branch. A harmonic filter circuit diagram, in the same search, is that passive sheet.
Does the Andeli page print that LC branch?
The page prints no reactor value and no capacitor value. The printed principle is the IGBT compensation current. A reader who needs the LC branch uses the electrical installation guide.
What does the page say the IGBT current does?
The IGBT outputs a compensation current with the same amplitude and opposite phase as the load harmonic current. That sentence is the active injection the page prints. It describes current amplitude and phase.
What harmonic range and response time does the page print?
The 400 V series block prints a compensation scope of 2-50 times, a harmonic compensation rate greater than 92%, and a full response time less than 40 ms. Those three statements are the series-block line a buyer can quote.
Does a passive tuning formula apply to this active filter?
The calculator page says the simple LC resonance model does not apply to an active filter. The formula on that page is for a passive single-tuned filter. The active unit stays with the injection paragraph.
What connection question did the forum poster ask?
On a forum thread, a poster asked whether a shunt passive filter still works if the non-linear load is not connected to ground. A reply treats the shunt branch as a parallel path, with the return on the second conductor. The same thread also asks whether a delta connection blocks the third harmonic.
What component values does the Andeli page leave off?
The page prints no reactor value and no capacitor value. The printed lines are the injection principle and the compensation line. Reactor and capacitor values stay with a passive-filter document.
References
- Harmonic filter design calculator, on the limit of the simple LC resonance model for an active filter: https://calcengineer.com/electrical/harmonic-filter-design/.
- Physics Forums thread on passive harmonic filters, the shunt path, and the poster's ground question: https://www.physicsforums.com/threads/passive-harmonic-filters-power-system.926438/.