Leave Your Message
News Categories
Featured News

High Voltage AC Vacuum Load Switch

2026-10-09

A high voltage AC vacuum load switch on this page is the indoor FZ(R)N25-12 family, and the table splits into two columns. One column is the load-switch rating. The other is the fuse combination.

A buyer who types the shared name can land on a product table or on a keyword page that prints a different set of numbers. The product page is the table quoted below. The two columns do not share one current rating.

The photographs show three red poles on a metal frame, with white interrupter housings and a side operating mechanism. They are chassis views of this family. They are not a single-line diagram.

Three-phase Andeli vacuum load switch with red shed insulators, white interrupter housings, bottom terminals, and a left-side operating mechanism.

The front view shows three red poles with shed insulators at the top, white interrupter housings in the middle, and metal terminals at the bottom. The operating mechanism sits on the left of the frame. The photograph is the hardware under the title, and the ratings still have to be read from the table.

What This Page's Name Refers To

The page is the indoor AC vacuum load switch family for three-phase distribution. The application text for the load-switch form keeps the unit indoors and names the frequency and voltage that sit with that form.

City distribution, industrial power equipment, ring networks, terminal supplies, and box-type substations are the uses the opening paragraph names. The same paragraph says the combination form is for load control and short-circuit protection. Those words are the page's own scope, not a second product.

A vacuum load switch, in the language of this page, is the device that sits in that indoor family. A keyword alias page may print another parameter table. That alias table is not the table quoted below.

The load-switch hub on this site lists more than one product. The quotes below stay on the FZ(R)N25-12 product page. An air load-break switch on the same hub is a different line.

What the Load-Switch Column Prints

The load-switch column is quoted as one printed block so the numbers stay together. The table column headed FZN25-12D/T630-20 prints rated voltage 12 kV, rated frequency 50 Hz, rated current 630 A, and rated power load breaking current 630 A.

That column is the load-switch rating a buyer can quote for voltage, frequency, continuous current, and load breaking current. The open-circuit breaking current cell in that column is a dash. The dash means the page does not print a fault-breaking number there.

Closed-loop breaking current, cable charging current, and no-load transformer capacity also appear as printed cells on that same column. Those special-duty cells stay with that column. They do not move onto the fuse-combination column.

The application paragraph for the load-switch form says the switch is for dividing load current, loop current, no-load transformer current, and cable charging current. That sentence matches the column that carries the load-breaking line. It is not a sentence about a vacuum circuit breaker.

Side view of the three red poles with white interrupter housings, bottom contact blades, and a right-side linkage on a metal frame.

This side view shows the three poles, the interrupter housings, and the bottom contact blades. The linkage on the side of the frame is the mechanical path that moves the poles together.

The photograph shows the chassis. The load-switch line stays in the table.

What the Fuse Combination Column Prints

The combination column is quoted next, and both model strings stay visible. The table column headed FZN25-12D/T125-31.5 prints rated current 125 A and rated open circuit breaking current 31.5 kA. The prose names FZRN25-12D/T200-31.5 for the fuse-combination unit.

Both labels are printed on the same product page. A submittal that uses only one of them has dropped a string the page still shows. The table header and the prose model are not cleaned into one name here.

That column also prints a lower load-breaking current, a transfer-current cell, fuse-model names, and a striker-energy cell. Those cells belong to the combination column. They are not copied onto the load-switch column.

The combination paragraph says the unit is for load control and short-circuit protection, that a grounding switch can withstand short-circuit current, and that the actuator can be manual or electric. That paragraph is the place the page attaches short-circuit talk to the fuse combination. It is not the place to paste a breaker catalog number onto the load-switch column.

A buyer who needs short-circuit interruption from this family is reading the combination column, not the load-switch column. The dash in the load-switch open-circuit cell is the reminder.

Frame-mounted three-pole vacuum load switch with a black drive shaft, large black spring on the right, and oval mounting holes in the side rails.

The frame view shows a black drive shaft across the poles and a large black spring on the right side of the mechanism. Oval mounting holes run down the side rails.

The photograph is still the same family of hardware. The combination ratings remain in the table.

What the Switch Standard Covers

The catalog abstract is the only place these paragraphs take the switch standard from. IEC 62271-103:2021, on the catalog page, applies to three-phase AC switches and switch-disconnectors above 1 kV up to and including 52 kV.

That sentence is the catalog abstract. It describes a family of AC switches. It does not appear on the Andeli product page.

Quoting the catalog is fair. Pasting it onto the nameplate invents a certificate the page does not print.

The opened preview of that standard also says a breaking operation should not immediately follow a making operation, because the current to be broken may then exceed the rated breaking current of the switch. That sequence caution stays in the preview. It is not rewritten here as an Andeli operating card.

A commercial explainer that assigns one catalog family to load-break switches and another to circuit breakers is using those catalog numbers as a teaching split. Its ampere bands stay in that explainer. They do not replace the two Andeli columns.

What a Forum Keeps Apart

A Physics Forums reply separates a load-break switch, which interrupts its maximum rated load, from a circuit breaker, which interrupts fault current.

Important: On that Physics Forums thread, a reply said: "AN LBS is designed for interrupting the max rated load - and doing it multiple times... a CB is designed for interrupting the max Interrupting Current (IC) - that will be experienced in a fault."

The reply's own ampere examples stay in the thread. They are not Andeli ratings. The useful part is the split: rated load on one side, fault current on the other.

An Eng-Tips thread about a load-break switch beside a vacuum contactor treats the switch as isolation when the contactor is doing the motor switching. That thread is a motor-control discussion.

It does not rewrite the Andeli table. If a reader needs that isolation argument, the thread is the place to keep it.

A buyer who pastes a breaker interrupting number onto the load-switch column has switched documents. The load-switch column on this page prints load breaking current and leaves the open-circuit cell blank. The forum's breaker side of the split is the place for fault current.

What the Page Leaves Off

The absences close the quote. The product page does not name IEC 62271-103. The load-switch column does not print an open-circuit breaking current.

Column What it prints What it leaves blank
Load-switch column Voltage, frequency, current, and load breaking current Open-circuit breaking current
Combination column A lower current and an open-circuit breaking current A single shared current with the other column
Prose combination model A second model string beside the table header A merge with the table header string
Document What a buyer can take from it
Andeli product page The two columns and the two combination labels
Switch-standard catalog The AC-switch voltage band in the catalog abstract
Physics Forums reply The load-versus-fault split, not an Andeli ampere

The FZ(R)N25-12 indoor AC high voltage vacuum load switch is the page that prints both columns. Open it when the next question is which rating to quote. When the next question is a vacuum circuit breaker interrupting rating, that answer is not in the load-switch column's open-circuit cell.

Related load-switch reading on this site sits on the load switch hub. That hub is the upward path. The product page is the downward path for this indoor vacuum family.

Three red insulating columns with viewing windows over white interrupter parts, bottom terminals, and a left panel with a schematic and a yellow warning label.

This view shows the three red columns, the viewing windows over the interrupter parts, and a left panel with a schematic and a yellow warning label. It is the chassis a submittal can attach to the table. The table still has to say which column is in play.

A decision that stays honest can finish in two quotes. The load-switch column is the load rating. The combination column is the short-circuit side of this family, with both model strings kept.

The catalog standard and the forum split stay in their own documents.

FAQs

What does the product page call this switch?

The page calls the family the FZ(R)N25-12 indoor AC high voltage vacuum load switch. The application text for the load-switch form keeps the unit indoors and names the frequency and voltage that sit with that form. City distribution, ring networks, and box-type substations are the uses the opening names.

What does the load-switch column print?

The table column headed FZN25-12D/T630-20 prints rated voltage 12 kV, rated frequency 50 Hz, rated current 630 A, and rated power load breaking current 630 A. The open-circuit breaking current cell in that column is a dash.

What does the fuse-combination column print?

The table column headed FZN25-12D/T125-31.5 prints rated current 125 A and rated open circuit breaking current 31.5 kA. The prose names FZRN25-12D/T200-31.5 for the fuse-combination unit.

Why do the prose and the table use different combination model strings?

Both strings are printed on the same product page. The table header uses one combination string. The prose uses another.

A quote that keeps both strings stays with the page.

Does the page name IEC 62271-103?

The product page does not name IEC 62271-103. The catalog abstract covers three-phase AC switches in the voltage band named on that catalog page. That abstract stays on the catalog page.

How does the forum separate a load-break switch from a breaker?

A Physics Forums reply says a load-break switch interrupts its maximum rated load, and a circuit breaker interrupts the interrupting current of a fault. The reply's ampere examples stay in the thread. They are not Andeli ratings.

What does the page leave off?

The page does not name the switch standard from the catalog. The load-switch column does not print an open-circuit breaking current. A vacuum circuit breaker interrupting rating is not sitting in that dash cell.

References

  • Catalog abstract for alternating current switches above one kilovolt through the band named on that page: https://webstore.iec.ch/en/publication/64656.
  • Physics Forums thread separating a load-break switch from a circuit breaker: https://www.physicsforums.com/threads/difference-between-a-circuit-breaker-and-a-load-break-switch.941232/.