HRC Fuse Diagram
An hrc fuse diagram on this product page is the fuse link dimension table plus a photograph of the barrel. A drawing office often expects a circuit symbol. The page that carries the hardware name prints sizes and a picture instead.
The words cylindrical contact caps appear in the application paragraph, and the photograph shows the silver ends those words describe. Read the table, the paragraph, and the red print as three records.

What the Diagram Query Is Asking
The query is asking for a drawing, and this page answers with a size table and a barrel photograph. Someone searching the phrase usually has a single-line sheet open and wants a small mark to drop on a feeder.
That mark lives in a drawing standard. The product page is a hardware page. Putting the two jobs in one search is how a symbol request lands on a fuse link.
A schematic mark has to be small, repeatable, and the same on every sheet in a set. A product photograph is the opposite kind of picture. It shows one object, with caps, a barrel, and lettering, and it changes when the camera moves.
The useful split is simple. Take the symbol from the drawing practice your office already uses.
Take the size and the printed marks from the product page. The page does not try to be both.
People also paste a generic fuse outline into a buying note and then ask the factory to confirm it. The factory page cannot confirm a sketch it never drew. It can confirm the table cells and the photograph.
Keep the search phrase as a request for a picture. Then notice which picture arrived.
A table of millimetre sizes is a picture of dimensions. A barrel photo is a picture of the object. Neither one is a schematic glyph.
The Application Line Beside the Caps
The application paragraph is the duty line for distributing installations, and it names the contact shape before it names the duty. Cylindrical contact caps are the ends of the link, the silver pieces a holder grips.
The application paragraph prints cylindrical contact caps, a rated voltage of 380V AC, and a rated current up to 125A.
That sentence is the application paragraph, not the red print on the barrel. Overload and short circuit are the two faults the same paragraph says the links address. Striker links are mentioned for motor single-phasing when the link sits in a fuse isolator.
A buyer who copies only the barrel into a data sheet will miss this paragraph. A buyer who copies only this paragraph will miss the red print. Both lines are on the page, and they are not the same line.
Read the contact words first. They tell you the link is a cylinder with caps, which is why the photograph looks the way it does. Then read the voltage and current in that same paragraph, and leave them there.
The striker note is a use hint, not a drawing. It says the striker version is for a motor case when the link is fitted in an isolator. It does not draw the isolator, the motor, or a trip circuit.
If a note in your project says "see diagram," attach the table and say which paragraph you quoted. That is the honest way to answer a diagram request with this page.
The Millimetre Row for RO15
The specification table is the fuse link dimension table, with characteristic letters, type codes, millimetre sizes, and current lists. The characteristic columns are headed gG and aR.
The specification table prints RO15 and RS15 at 10*38 mm.
Quote that row when the type code on your note is RO15 or RS15. The letters on the barrel in the photograph are not a license to rewrite the table code. Leave RO15 as RO15.
| Characteristic | Type codes | Size cell |
|---|---|---|
| gG and aR | RO15 and RS15 | 10*38 mm |
Other rows on the same table use other type codes and other size cells. Stay on the row whose code matches the link you are buying. A neighbouring row is a different link, even when the characteristic letter looks familiar.
The current list sits in the same row as the size. Read the list as the page printed it, in that cell, rather than as a single number pulled from memory. If your project needs one current from the list, name the row and the list together.
gG and aR are column labels, not a ranking. The page does not tell you to prefer one letter. It prints both, and the row you need depends on the duty your holder and your load already call for.
A dimension table is what many people mean when they say diagram and then accept a size. The millimetre cell is the drawing. It says how long and how wide that row's link is, in the form the cell uses.
Do not carry a size from a keyword-alias page onto this table. Those alias tables were opened and they do not match this product table. The row above is the one on the product page.
Red Print on the White Barrel
The upright photograph is a white barrel with silver end caps and red lettering, and that lettering is its own record. Call it a fuse link, because that is the object between the caps.
The upright photograph prints R015, 10X38, 690V~50KA, aR 32 A, and IEC60269 on the white barrel.
That print is ink on the barrel in the photograph. It is a photograph record, separate from the specification table.
The type token on the barrel is R015. The type token in the table row above is RO15. Leave both spellings as they appear.
Important: On a physics forum, a poster said a fuse catalog can show a rated current and another value called minimum breaking current, and asked what the second value means.
The post is about two currents in one catalog. The example amperes in that thread stay in that thread.
The lesson that travels is narrower. Two figures on fuse paper can describe different duties, so they should not be averaged into one number.
Here the split is already visible without leaving the product page. The application paragraph has its voltage and current. The barrel has its own red line.
A reader who needs the application duty quotes the paragraph. A reader who is looking at the object quotes the photograph.
Side views in the gallery are the same kind of barrel turned. They still show a white body and metal caps. They are not outline drawings, and they are not a substitute for the size cell.

When you write the alt text or the caption for a buyer, describe the barrel and the caps. If you also transcribe the red line, label it as print on the barrel. That label stops the transcription from being filed as the table.
The standards token on the barrel is part of that red line. It is not, by itself, a statement that every row of the table was certified. The table does not repeat that token in the cells reviewed for this page.
The Catalog Name for Cylindrical Caps
The catalog abstract is a third paper, separate from both the table and the barrel. It is where a standards seller describes a fuse system, not where this factory prints its size row.
The catalog page for IEC 60269-2 names fuse system F as fuse-links having cylindrical contact caps.
Fuse system F is the catalog's name for links with that contact shape. Cylindrical contact caps are the same shape the application paragraph names and the photograph shows. The catalog does not quote the RO15 cell, and it does not quote the red line.
| Record | What it is safe to say |
|---|---|
| Application paragraph | Contact shape plus the duty line in that paragraph |
| Barrel photograph | Red print on the white barrel |
| Catalog abstract | Fuse system F for cylindrical contact caps |
A general-requirements abstract for the same fuse family covers enclosed current-limiting links. Its numeric floor stays in that abstract. It is not copied into the Andeli table, because the table does not print it.
An older dimensional example that mentions cylindrical caps also says it is not the place that standardizes characteristics, and that part has been replaced. It is not a certificate for this link.
Use the catalog sentence when someone asks what the standards trade calls this contact shape. Use the product table when someone asks what size this page prints. Those are different questions, and they stay answered on different pages.

Marks This Page Does Not Draw
The page does not draw a circuit symbol, a holder outline, or a motor circuit around the striker. The photograph and the table are the diagrams it actually gives you.
If your sheet needs a symbol, take it from the drawing standard your project already specifies. Then point the bill of material at the H.R.C fuse core for the table and the photograph. The fuse category list sits under the fuse hub.
The application article already explains where this kind of link is used. This page does not retell that story. It stays with the picture the diagram query asked for.

A clean handoff has three attachments and no merged line: the application sentence, the RO15 size sentence, and the barrel sentence. Each one keeps the source it came from.
Alias pages that offer a different voltage table were set aside. They do not replace the product table. A breaking-capacity number that appears only in a standards abstract stays in that abstract.
When the red print and the application paragraph disagree, the disagreement stays visible. Editing one of them so the file looks tidy would hide the page you are actually buying from.
FAQs
What does the diagram query expect from this page?
It expects a drawing. This page supplies a dimension table and a photograph of the barrel, which is the diagram the product page can stand behind.
What voltage and current does the application paragraph print?
Read the application paragraph on its own, and keep it apart from the red print.
The application paragraph prints cylindrical contact caps, a rated voltage of 380V AC, and a rated current up to 125A.
Which millimetre size does the RO15 row print?
Stay on the RO15 and RS15 row, and keep the type code spelled the way the table spells it.
The specification table prints RO15 and RS15 at 10*38 mm.
What red print is visible on the upright barrel?
Transcribe the upright photograph, and label the transcription as barrel print.
The upright photograph prints R015, 10X38, 690V~50KA, aR 32 A, and IEC60269 on the white barrel.
Does the product page draw a circuit symbol?
It does not. The visuals are the size table and the barrel photograph. A schematic mark has to come from the drawing standard on your project.
What name does the catalog give cylindrical contact caps?
The catalog uses a system name for links with that contact shape. It does not quote this table.
The catalog page for IEC 60269-2 names fuse system F as fuse-links having cylindrical contact caps.
Which marks stay off this product page?
A circuit symbol, a rewritten type code, and a breaking-capacity floor copied from a general-requirements abstract. The page also does not merge the application voltage into the barrel print.
References
- Cylindrical contact cap catalog: https://webstore.iec.ch/en/publication/96037
- Fuse catalog currents thread: https://www.physicsforums.com/threads/fuse-breaking-current-explained.411100/