Low Voltage Switchgear Specification

2026-10-10

A low voltage switchgear specification on this cabinet page is the printed GGD table, read with both voltage paragraphs still in view. The gear is assembled fixed panel switchgear. The short-time withstand current belongs to the row you quote, for the time the column header states.

A cleaner-looking sentence later on the page is not a reason to hide the opening sentence. The table is not a reason to borrow a breaking cell from a neighbouring row.

Grey cabinet with the left doors closed, the right side open onto empty compartments, and a blue header

What Belongs in the Quote

A specification quote from this page has to carry the row you mean and the two voltage paragraphs around it. Fixed panel means the devices stay in the assembly rather than rolling out on a truck. That construction phrase is part of how the page introduces the cabinet.

Power plants, substations, and industrial users are the audiences the page names. The work it names is power conversion, distribution, and control. Those words tell you the cabinet is distribution gear, and they do not replace the table.

People often want one line they can paste into a data sheet. One line is how a neighbouring row's breaking cell ends up on the wrong model. The paste should be the row, with the model name still attached.

The photographs show grey cabinets, doors, and, on one view, colored busbars. They are evidence of the hardware.

They are the hardware view. A busbar color in a photo is a color, and the current stays in the table.

If a buying note says "per specification," attach the row and say which paragraph the voltage came from. A photo of an open door does not answer that note.

The hub that lists this cabinet beside other low-voltage gear is the low-voltage switchgear category. Withdrawable families on that list have their own pages. Their busbar figures stay on those pages.

Two Voltage Sentences on One Page

The page prints the working voltage twice, and the two sentences do not match. The opening frequency token is garbled. Leave the token as printed rather than repairing it in the quote.

One paragraph prints a rated working voltage of 300v, and a later paragraph prints AC 50Hz with a rated working voltage of 380V and a rated current to 3150A.

Both sentences stay in the quote. Deleting the opening sentence because the later one looks more familiar would hide a line the page actually printed. Deleting the later sentence because the opening one came first would hide the line the table's voltage cell agrees with.

Paragraph What to keep visible
Opening paragraph The voltage that paragraph prints, garbled frequency token included
Later paragraph The frequency, voltage, and current that paragraph prints

The table rows reviewed below print their own voltage cell. That cell is part of the row. It does not erase the opening paragraph.

A reader can see the tension and still refuse to invent a third number that appears on neither line.

Short-time withstand is also named in the opening paragraph, as a ceiling. The row-by-row cells are the place to quote a model. A ceiling in a preface and a cell in a row are different sentences, and a quote should say which one it used.

Grey cabinet with both doors closed and ventilation slots across the doors

When you send the quote onward, paste both sentences and then the row. Add a short label on each paste so a later reader can see they came from different places on the same page. That label is the whole protection against a tidy merge.

The GGD1 Row Left Intact

The GGD1 row is a full specification by itself. Its current cells, its breaking cell, its withstand cell, and its peak cell stay together.

The GGD1 row prints 380 V, currents of 1000 A, 600(630) A and 400 A, a short-circuit breaking current of 15 kA, a one-second short-time withstand of 15 kA, and a peak withstand of 30 kA.

Short-time withstand current on this row is the one-second cell, and it stays at the time the header states. The peak cell is a different column.

Breaking current is another column. They share a row, and they do not share a meaning.

Model Voltage Current cells Breaking One-second withstand Peak
GGD1 380 V 1000 A, 600(630) A, 400 A 15 kA 15 kA 30 kA
GGD2 380 V 1500(1600) A, 1000 A, 600 A 30 kA 30 kA 63 kA
GGD3 380 V 3150 A, 2500 A, 2000 A 50 kA 50 kA 105 kA

GGD2 is in the table so the middle row stays visible. Quote it from the table when the model is GGD2. Do not build it by averaging the rows above and below it.

The parenthetical currents are printed that way. Keep the parenthesis. Smoothing 600(630) into a single preference would be an edit, not a reading.

A fixed panel cabinet at this row is still the same construction story as the rest of the page. The row does not become withdrawable gear because a project prefers a truck. If the project needs a withdrawable assembly, that is a different product page.

The GGD3 Row Left Intact

GGD3 is the highest row in the table. Its cells are its own, including the current, the breaking current, the withstand, and the peak.

The GGD3 row prints 380 V, a current of 3150 A, a short-circuit breaking current of 50 kA, a one-second short-time withstand of 50 kA, and a peak withstand of 105 kA.

The breaking cell on GGD1 does not travel to this row. The peak cell does not travel either. A reader who remembers only the largest number on the page and writes it beside every model has left the table.

The later prose current and this row's current cell can be mentioned together only if you say which sentence is which. The row sentence above already carries the row.

The voltage paragraph carries the preface. They can sit in one email as two quotes. They should not be rewritten into a third sentence the page never printed.

An open-door photograph shows busbars and breakers inside a cubicle. That view supports the claim that the cabinet is assembled gear.

It does not show which row you bought. The row name has to be in the text.

Open cabinet showing red, green, and yellow busbars, breakers, and red components along the bottom

Alias pages for this cabinet were opened and set aside. Their benchmark tables do not match this specification table. A quote that needs to survive a check should come from the product page, not from the alias.

A Forum Formula Stays Off the Row

The column header states the time that belongs to the withstand cell. The page prints no note that tells you to change that time with a formula.

Important: On a physics forum, a poster asked how to stretch a short-time rating out to a longer duration, and a reply said the answer depends on the particular equipment.

That reply refuses a universal stretch. The example currents and durations in the thread stay in the thread.

What you can take is the habit of leaving the time beside the current.

A second thread makes the same split in different words. People compared a longer nameplate time with a shorter one and treated them as different duties. Dynamic force and thermal heating were not used as nicknames for the same cell.

If your study needs a withstand at some other duration, that study is extra work. It is not a cell on this page, and it should not be typed back into the GGD row as if the factory had printed it.

The one-second wording in the sentences above is the wording that matches the table header. Keep the header when you transcribe the cell. A bare current with the time deleted is a different claim.

No torque, no busbar spacing, and no device layout are printed as part of these rows. The open cubicle shows hardware.

It does not give a drill plan or a wiring schedule. A distribution-box build article already covers a different enclosure, and it should not be borrowed as a construction guide for this cabinet.

A Catalog the Page Does Not Name

A standards catalog describes general rules for low-voltage assemblies. Naming that catalog in a quote is fair only when you also say the product page never prints the number.

The catalog page for IEC 61439-1:2020 lays down general rules for low-voltage switchgear and controlgear assemblies, and the AGGD page does not name that number.

The catalog identifier in that sentence is the name for those general rules. The cabinet page does not print it as a certificate.

Another family's page that names its own standards stays on that family. Those standards and those busbar currents are not pasted onto this table.

The cabinet to open for the table and both voltage paragraphs is the AGGD low-voltage distribution cabinet. Use it when the model in your note is AGGD or the GGD row names on that page.

Cabinet lineup with meters on the doors and a breaker visible in a window

A comparison between GGD and another low-voltage family already exists as its own article. This page does not rerun that comparison. It quotes the AGGD table.

A specification that will be checked later should show the opening voltage sentence, the later voltage sentence, and the single row that matches the model. The catalog sentence can sit in a footnote if someone asks what general assembly rules exist in the trade. It cannot sit in the row as if the factory had printed it there.

FAQs

What has to stay in a specification quote from this page?

The row for the model you mean, plus both voltage paragraphs. A photograph of the cabinet does not replace the row.

Which voltage does the opening paragraph print?

Keep the opening paragraph and the later paragraph as two quotes.

One paragraph prints a rated working voltage of 300v, and a later paragraph prints AC 50Hz with a rated working voltage of 380V and a rated current to 3150A.

What does the GGD1 table row print?

Quote the whole GGD1 row, including breaking, withstand, and peak as separate cells.

The GGD1 row prints 380 V, currents of 1000 A, 600(630) A and 400 A, a short-circuit breaking current of 15 kA, a one-second short-time withstand of 15 kA, and a peak withstand of 30 kA.

What does the GGD3 table row print?

Quote GGD3 from its own cells. Do not reuse the GGD1 breaking cell.

The GGD3 row prints 380 V, a current of 3150 A, a short-circuit breaking current of 50 kA, a one-second short-time withstand of 50 kA, and a peak withstand of 105 kA.

Why do two paragraphs print different voltages?

The page printed both. A quote that hides one of them is an edit. The table's voltage cell can be shown beside them without deleting either sentence.

Does the cabinet page name the assembly general-rules catalog?

The cabinet page does not name it. The catalog page is a separate document.

The catalog page for IEC 61439-1:2020 lays down general rules for low-voltage switchgear and controlgear assemblies, and the AGGD page does not name that number.

What formula does the page refuse to print?

Any rescaling of the one-second column. Forum talk about peak force versus heating can explain why the time stays in the quote. It cannot add a new duration to the row.