Single Phase Pole Mounted Distribution Transformer
Single phase pole mounted distribution transformer, on the Andeli page, is an overhead tank with hanger brackets for direct pole mounting. The same page sends that tank toward rural power grids, remote areas, and dispersed villages, and the pad-mounted cabinet stays in another article.
The search is for a pole tank, so the page to read is the single-phase overhead transformer. A locked steel cabinet on a concrete pad is a different product and a different article.
What the Pole Search Is Asking
People type this query when they can see a cylinder on a pole and want the manufacturer's words for it. The overhead page answers with a mild steel tank and brackets, not with a walk-in enclosure.
Pad-mounted articles already explain a locked cabinet. Quoting those articles here would describe the wrong shape.
A buyer comparing a pole line with an underground pad can keep both names, as long as each name stays on its own page. This page is the cylindrical tank.
The photograph shows a white cylinder, two ribbed bushings on the cover, and a row of side terminals. That is the hardware the mounting sentence belongs to.
Stencil marks on the tank are left in the photograph and out of the sentences. A stencil is not a second rating table.
Hanger Brackets for Pole Mounting
The feature list says how the tank is hung.
Mild steel tank with welded lifting lugs and hanger brackets for direct to pole mounting.
Pole mounting is the phrase a buyer can search, and the page prints it as direct to pole mounting. Lifting lugs are in the same sentence, so the tank can be lifted and then hung.
The cover hardware in a labeled photograph includes a cover clamp, lifting lugs, and a support lug. Those callouts match the feature sentence without adding a new rating.
Side terminals and cover bushings are visible on the white tank. The page also says the high-voltage bushings are porcelain and cover mounted, and the low-voltage bushings can be porcelain or polymer.

A second view shows the same kind of cylinder with a lifting bracket on the side and a short row of terminals. The bracket is the hardware a reader can point at when the sentence says hanger brackets.
The tank is an overhead transformer on the hub. That series name is the shelf where this pole unit sits, next to other transformer families that are not pole tanks.
Where the Page Says the Tank Belongs
The page names the places in one sentence.
Suitable for rural power grids, remote mountainous areas, and dispersed village energy transformation.
Rural power grids are the first place. Remote mountainous areas and dispersed villages follow in the same sentence.
The opening also says the tank uses a sealed structure, has a strong overload capacity, and is simple to maintain. A garbled loss phrase in that opening is left unquoted, because the words on the page do not form a clean percentage.

The labeled photograph points at a pressure relief, a tap changer, a tank ground, and a ground connector. Those words are printed on the picture as callouts.
They are not a new specification table.
A buyer writing a rural project note can paste the places sentence. The note still needs the utility's own primary voltage, which this page does not settle inside the definition.
The ANSI Tokens as Printed
The feature list names two ANSI tokens, and it prints them with spaces.
All units are built in accordance with both ANSI C57 12.00 and ANSI C57 12.20, except as modified to comply with customer specifications.
The spaces in those tokens are part of the printing. Closing the spaces would make a search miss the page.
The same list says the exception is a customer specification. The page does not show a filled example of that exception.
Other features in the list are a clamped cover band, polyester powder paint, tin-plated bronze terminals, an insulated cover for wildlife protection, a laser engraved aluminum nameplate, and non-PCB insulating oil. Each of those is a feature line, not a test result.

| What this page prints | What stays in the pad article |
|---|---|
| Hanger brackets for pole mounting | Locked steel cabinet |
| Rural grids, remote areas, villages | Concrete pad definition |
| ANSI tokens with the printed spaces | Box ratings and the installation table |
The left column is the overhead page. The right column is the other article.
A Forum Remark About the Pole Unit
A forum thread asked how a pole-mounted transformer is wired. One reply described the unit as single-phase.
Important: A single-phase, as is the case in one pole mounted distribution transformer, as well uses the neutral from a three phase system.
The reply is about the neutral, not about a conductor size. Voltage figures elsewhere in pole threads stay in those threads.
The sentence matches the query's single-phase wording. It does not replace the hanger-bracket sentence, which only the product page prints.
Other replies describe a house service and a ground spike. Those steps are the house end of the line, and they are not a mounting instruction for this tank.
The Pad-Mounted Article Stays Separate
The pad article owns the locked cabinet and the American-style box. This article owns the cylindrical overhead tank.

Open the single-phase overhead transformer for the bracket sentence. The transformer hub is the shelf that lists this series beside the other families.
| Sentence to keep | Why it stays here |
|---|---|
| Hanger brackets for direct pole mounting | It is the mounting sentence |
| Rural grids and dispersed villages | It is the place sentence |
| ANSI tokens as printed | The spaces are part of the line |
The outline drawing shows four views of the cylinder with letters for the dimensions. The letters stay letters on the drawing.
A reader who needs the pad cabinet should leave this page and open the pad definition. The photographs will not match, and that mismatch is the point.
The cylinder in the studio shots is the tank a lineworker would see from the pole. The white paint and the cover band are visible without reading a stencil.
Two ribbed bushings rise from the cover. The feature list calls the high-voltage ones porcelain and cover mounted.
Side terminals sit in a row on the cylinder wall. The page allows porcelain or polymer for the low-voltage bushings.
A lifting bracket on the side is the hardware behind the hanger-bracket sentence. The photograph and the sentence can be read together.
Wildlife protection is an insulated cover in the feature list. The page does not draw the animal guard.
The nameplate is described as laser engraved aluminum. The photographs are not used as a substitute for that plate.
Non-PCB oil is printed as a feature. The article does not convert that line into a fill volume.
Powder paint and a clamped cover band are construction lines. They explain the sealed tank in plain shop language.
Tin-plated bronze terminals are another feature line. They are the metal the page names at the bushing ends.
The hub lists this overhead series on its own. Oil-immersed distribution tanks and dry-type series stay on their own links.
A village project and a pad-mounted site can both be real work. They are not the same enclosure.
The forum reply uses the words pole mounted distribution transformer. That is the query, said from the line side.
The neutral remark is the only forum sentence copied here. House-wiring steps stay in the thread.
Dimension letters on the outline are A, B, C, and D in the drawing. They are letters, and the drawing is left without assigned lengths.
Callout words such as pressure relief and tap changer are labels on the picture. Quoting a label is not the same as quoting a test.
A support lug and a tank ground are also labeled. A crew can look at the picture and then read the feature sentence.
The pad article's concrete pad is the wrong mounting surface for a sentence that says pole mounting. The two surfaces answer two different questions.
Customer specifications are the exception inside the ANSI sentence. The page leaves that exception open.
A fully sealed structure is part of the opening description. The opening also says maintenance is simple.
Overload capacity is named, without a second number beside it in the places sentence quoted above. The loss table is left on the product page.
Remote mountainous areas are printed next to rural grids. The page does not add a road or a span length.
Dispersed village energy transformation is the last place in that sentence. It is a use, not a design calculation.
The white tank in the recommendation drawing is the same family of cylinder. Four views show the cover bushings and the side brackets.
A reader who only needs the bracket sentence can stop at the feature list. The rest of the product page is there when the project needs it.
Studio photographs use a white background. They are product views, not a picture of an installed pole.
The ANDELI mark appears in the corner of the studio shots. The hardware description stays with the tank, the bushings, and the brackets.
FAQ
What mounting hardware does the overhead page name?
Welded lifting lugs and hanger brackets for direct pole mounting, on a mild steel tank.
Where does that page say the tank is used?
Rural power grids, remote mountainous areas, and dispersed village energy transformation.
How are the ANSI tokens printed?
With spaces, as ANSI C57 12.00 and ANSI C57 12.20, inside the feature sentence.
What did the forum reply say about the pole unit?
One pole mounted distribution transformer is single-phase and uses the neutral from a three phase system.
Is this the pad-mounted cabinet?
The pad-mounted cabinet is a different enclosure and a different article.
Do the photograph stencils become a rating table?
The stencils stay in the photographs. They are not copied into a rating table.
Which article owns the pad definition?
The pad-mounted definition article owns the locked cabinet. This article stays with the pole tank.
References
- Pole-mounted transformer thread: https://www.physicsforums.com/threads/how-is-a-pole-mounted-transformer-wired.604429/
- Shared-neutral thread: https://www.physicsforums.com/threads/shared-neutral-between-distribution-and-split-phase.741406/














