S9-35kV Series Transformer - High Efficiency & Low Loss from China Suppliers and Factory
π― Product Features
Product has high efficiency, low loss, low noise characteristics;
Internal heat, and short circuit capability;
Empty, load loss is low;
Reliable operation, long life, maintenance-free.
π Application Standards
IEC 60076-1-2-3 2000 Power Transformer
GB 1094.1-2-1996 Power Transformer
GB 1094.3-5-2003 Power Transformer
GB/T6451-1999 Technical parameters and requirements for three-phase oil-immersed power transformer
π·οΈ Transformer Model Description
π€οΈ Transformer Normal Service Conditions
The height above the sea level is below 1000m
Ambient Temperature:
Highest air temperature +40β
Highest daily average air temperature +30β
Highest annual average air temperature +20β
Lowest outdoor air temperature -25β
β οΈ Transformer Special Service Conditions
The height above the sea level is above 1000m
Ambient Temperature:
Highest air temperature is above 40β
Lowest air temperature lower than 25β
βοΈ Performance Characteristics
The features of this product are high efficiency and low loss. It can save a lot of operation cost, and the social benefits are very significant.
The iron cores are made of the imported high-conduction magnetism, cold-roll, and grain-oriented silicon-steel sheets. The iron cores and windings adopt the vacuum drying and vacuum oil-filling processes, which make the internal moisture down to the very low level.
The conservator is hermetically sealed, which make the internal running oil to isolate with oxygen and moisture efficiently.
The above features guarantee the transformer does not need to replace the oil during the normal operation, greatly decrease the maintenance cost, and prolong the service life.
β Frequently Asked Questions (FAQ)
What are the main features of the S9-35kv Series Transformers?
These transformers feature high efficiency, low loss, and low noise characteristics. They also offer strong internal heat and short circuit capability, ensuring reliable, maintenance-free operation with a long service life.
What application standards do these power transformers meet?
They strictly comply with international and national standards including IEC 60076-1-2-3 2000, GB 1094.1-2-1996, GB 1094.3-5-2003, and GB/T6451-1999.
What are the normal ambient temperature conditions for operation?
Under normal service conditions, the highest air temperature is +40β, the highest daily average is +30β, the highest annual average is +20β, and the lowest outdoor air temperature is -25β.
Under what conditions is the transformer considered to be in special service?
Special service conditions apply when the installation height is above 1000m above sea level, or when the ambient temperature exceeds 40β or falls below 25β.
How does the transformer maintain low internal moisture?
The iron cores and windings adopt advanced vacuum drying and vacuum oil-filling processes during manufacturing, which effectively reduces the internal moisture to a very low level.
Why is the transformer considered maintenance-free regarding oil replacement?
The conservator is hermetically sealed, efficiently isolating the internal running oil from oxygen and moisture. This guarantees that the transformer does not need oil replacement during normal operation, decreasing maintenance costs.