ZN63(VS1)-12 Vacuum Circuit Breaker

The ZN63 (VS1) -12 indoor high-voltage vacuum circuit breaker is a high-voltage switchgear widely used in power systems. The circuit breaker adopts a vacuum interrupter, which can effectively extinguish the arc in a very short time, reducing the damage caused by the arc to the equipment and improving the safety and reliability of the equipment. With its superior performance and reliability, it has become an indispensable and important equipment in the power system.

    Application

    The ZN63(VS1)-12 indoor high-voltage vacuum circuit breaker is designed for three-phase AC power systems, suitable for applications with a frequency of 50Hz and a rated voltage of 12kV. This circuit breaker is widely used in power grid equipment, power distribution systems in industrial and mining enterprises, and in locations requiring frequent short-circuit current interruption and operation, such as power plants, substations, and large factories. Its superior performance enables stable operation in a variety of complex power environments, ensuring the safety and reliability of power systems.
    ZN63(VS1)-12 (1)
    ZN63(VS1)-12 (2)
    This circuit breaker adopts unibody design of operating mechanism and circuit breaker technology, which can not only be used as fixed installation unit, but also can constitute the handcart unit with dedicated advanced mechanism.
    ZN63(VS1)-12 is indoor medium-voltage solid type seal vacuum circuit breaker, ZN63(VS1)-12vacuum breaker suitable for the insulation in the indoor air switch for 50Hz, rated voltage 12kVand below the grid from the control and protection, ZN63(VS1)-12 vacuum circuit breaker and the frequent need for short-circuit breaking current of occasions with very good performance,fully meet the requirements of automatic re-closing and have higher reliability and service life.

    Outline and Installation Dimension (mm)

    ZN63(VS1 (1)
    ZN63(VS1 (2)
    ZN63(VS1 (3)
    ZN63(VS1 (4)

    Main technical parameters

    No. ltem Unit Value
    1 Rated voltage kV 12
    2 High test operating voltage kV 12
    3 Rated current A 630 630 1250
    4 Rated short-circuit breaking current kA 20 25 21.5
    5 Rated short-circuit closing current kA 50 63 80
    6 Rated peak withstand current kA 50 63 80
    7 4Srated short time withstand current kA 20 25 31.5
    8 Rated insulation level P.F.withstand voltage(Before and after the rated breaking) kV 42(Fracture48)
    Impulse witstand voltage(Before and after the rated breaking) kV 75(Fracture84)
    9 Rated operating order   O-0.3S-CO-180S-CO
    10 Mechanical life times 3000
    11 Rated short-circult breaking current breaking times times 50
    12 Actuator Rated closing voltage(DC) V 110,220
    13 Actuator Rated opening voltage(DC) V 110,220
    14 Clearance between opencontacts mm 11±1
    15 Supper Travel(Compressed length of contact springs) mm 3.5±0.5
    16 Non corresponding time period between tri-phase opening and closing ms ≤2
    17 Bounce time of closing contacts ms ≤2
    18 Average time of opening s 0.9~0.12
    19 Average time of closing s 0.4~0.8
    20 Opening time ms 50
    21 Closing time ms 100
    22 Main loop resistance of each phase μΩ 60 50
    23 Allowed acumination thickness between moving contact and static contact mm 3