ZW32-12 Type Outdoor Vacuum Circuit Breaker
Application
The ZW32-12 outdoor high-voltage vacuum circuit breaker is a high-voltage power distribution device designed specifically for three-phase AC 50/60Hz power systems. Its rated voltage is 12kV and is suitable for outdoor environments. This device is primarily used to interrupt and close load currents, overload currents, and short-circuit currents in power systems, ensuring safe and stable operation. The ZW32-12 circuit breaker is widely used in substations, industrial and mining enterprises, rural power grids, and other locations requiring frequent operation, playing a vital role in circuit protection and control.
Designed with the specific requirements of outdoor use in mind, this circuit breaker features excellent waterproof, dustproof, and corrosion-resistant properties, ensuring reliable operation in a variety of adverse weather conditions. Furthermore, the ZW32-12 vacuum circuit breaker can also serve as a power sectioning switch, flexibly enabling power system distribution and management. When used in conjunction with a controller, this device can automate distribution networks, enhance the intelligence of power systems, and optimize the allocation of power resources.
In modern power systems, the ZW32-12 outdoor high-voltage vacuum circuit breaker not only improves the safety and reliability of power equipment, but also provides strong support for the efficient distribution and management of electricity. It is an important part of realizing smart grids and sustainable development.
Technical Parameter
| No. | ltem | Unit | Value |
| 1 | Rated voltage | kV | 12 |
| 2 | Rated frequency | Hz | 50 |
| 3 | Rated current | A | 630 |
| 4 | Rated short-circuit breaking current | kA | 20 |
| 5 | Rated peak withstand current | kA | 50 |
| 6 | Rated short-time withstand current (4 s) | kA | 20 |
| 7 | Rated short circuit close current (peak) | kA | 50 |
| 8 | Mechanical life | times | 10000 |
| 9 | Rated short open circuit current switching frequency | times | 30 |
| 10 | 1 min power frequency withstand voltage (wet) (dry) alternate with,on/fracture | kV | 42/48 |
| 11 | Lightning impulse withstand voltage (peak) relative to ground/fracture | kV | 75/85 |
| 12 | Secondary loop 1 min power frequency withstand voltage | kV | 2 |
Outline and Installing Dimensions(mm)
| 1.the outlet |
|
| 2.interrupter | |
| 3.insulation tube | |
| 4.next outlet | |
| 5.conductive clip | |
| 6.soft link | |
| 7.insulation rod | |
| 8.contact pressure spring | |
| 9.tripping spring | |
| 10.driver board | |
| 11.body output shaft | |
| 12.actuator | |
| 13.body box | |
| 14.CT |
| 1.Operating handle |
|
| 2.Isolation spindle | |
| 3.manual cut-off circuit breaker handle | |
| 4.story energy circuit breaker handle | |
| 5.cut-off instructions | |
| 6.wring plug | |
| 7.CT | |
| 8.insulators | |
| 9.insolation rack | |
| 10.insulation rod | |
| 11.wring board(inlet side) | |
| 12.isolated blade | |
| 13.wring board(outlet side) | |
| 14.circuit breaker |