ZW8-12 Vacuum Circuit Breaker

The ZW8-12G is available with either an internal PT (voltage transformer) or an external PT, allowing users to select the appropriate configuration based on specific application requirements. The internal PT design makes the device more compact and easier to install and maintain, while the external PT provides greater flexibility for diverse power monitoring and control needs. Designed to enhance the safety and reliability of power systems, the ZW8-12G is widely used in power plants, substations, and industrial distribution systems, ensuring stable operation under various operating conditions.

    Application

    ZW8-12 series high-voltage vacuum circuit breaker is a kind of outdoor high-voltage switch equipment with 50Hz three-phase alternating current 12Kv rated voltage. it mainly apply to break and close the load current, overload and short-circuit in country power net, city power net and mini-type power system. The general framework of this product adopts the form of three-phase using same box, i.e, put the three-phase arc-extinguishing chamber inside of the metal box. For the SMG material has the advantage of space insulation and grounding insulation, the breaker has perfect performance and high insulation strength.
    ZW8-12G is made of ZW8-12 circuit breaker and isolating switch, called the combination of circuit breakers, use for disconnect switches and self-prepare power supply. There are built-in PT and outer PT.
    This series of operating mechanism for the CT23-type spring operating mechanism energy storage can be divided into two kinds of electric and manual.

    Technical Parameter

    No. ltem Unit Data
    6.3kA 12.5kA 20kA
    1 Rated voltage kV 12
    2 Maximum working voltage kV 12
    3 Rated current A 630
    4 Rated short circuit load dropout current kA 6.3 12.5 20
    5 Rated short-circuit making current kA 16 31.5 50
    6 Rated peak withstand current kA 16 31.5 50
    7 Rated short time 1 min tolerance current kA 6.3 12.5 20
    8 Rated insulation level High-voltage test with working frequency kV 42
    Lightning shock pressure 75
    9 Rated operating sequence   Part-0.3S- Joint points -180S-Joint points
    10 Institutions life times 10000
    11 Rated short open circuit current switch frequency times 30
    12 Operating mechanism rated switching voltage V 110,220
    13 Operating mechanism rated points brake current V 110,220
    14 Contact clearance mm 11±1
    15 Super stroke (contact spring compression length) mm 3
    16 Three phase points, closing not synchronism ms ≤2
    17 Contact switching bounce time ms ≤2
    18 Average opening speed m/s 1.0±0.2
    19 Average closing speed m/s 0.7±0.15
    20 Opening time The highest operating voltage s 0.015-0.05
    The minimum operating voltage 0.03-0.06
    21 Closing time s 0.025-0.05
    22 Each phase main loop resistance μΩ 120(≤200)
    23 Action contact allowed to wear accumulative thickness mm 3